User’s Manual
CD3000M-2PH up to 100A
C.D. Automation Srl
7
www.cdautomation.com
3. Ordering information
Model CD3000M 2PH
1
2
3
4
5
6
7
CD3000M-2PH
Ex:CD3000M 2PH/ 75A/ 400V
/
480V
/
460V
/
SSR/ ZC/
UL
1 Nominal current of CD3000M
15A
45A
25A
75A
35A
100A
2 Operating Load Voltage (incoming voltage supply)
Specify the value of the line supply.
3 Max VOLTAGE of CD3000M
480V
600V
The voltage on the identification label must be equal or more than
operating voltage. The minimum voltage supply to the load is 24V.
4 Auxiliary Voltage
230V
200÷230V ±15%; 10VA
460V
300÷460V ±15%; 10VA
600V
600V ±15%; 10VA (on request)
5 Input
SSR
4÷30VDC
0-10V
0÷10V analog input
4-20mA 4÷20mA analog input
10K pot Potentiometer
6 Firing
ZC
Zero Crossing
BF
Burst firing. Specify the number on ON cycles at 50% of
power.
7 Options
COMM
MODBUS protocol in RS485 is standard
EF
External fuses and fuseholders
NF
No fuses
CD-KP
External Keypad
HB
Heater Break Alarm
FAN110 Fan voltage supply 110VAC
±
15% (std 230VAC
±
15%)
14W 50/60Hz
UL
UL Certification