33
To use external control in Strobe Mode,
refer to items , , , and under
and
.
1
3
4
2
8
Inputting the External Trigger
7
Control with External Signals
External Trigger
Input Cable
(EXCB2-M10-3)
External Trigger
Input Cable
LAN cable
External Trigger
Input Cable
(EXCB2-M10-3)
LAN cable
External Trigger
Input Cable
LAN cable
Select the control mode and lighting mode from the following Application Guide and proceed to the indicated reference items.
*Data that has been set is retained even after the power is turned OFF with manual or external control.
The Light Units are always ON.
Power ON
Power OFF
Lit.
Not lit.
Control mode
Lighting mode
Application Guide
To use external control in Continuous Mode,
refer to items , , and under
.
1
3
2
7
Control with External Signals
To use manual control in Continuous Mode, refer to
items , , and under .
6
Manual Control
1
3
2
To use manual control in ON/OFF Mode,
refer to items , , and under
and
.
6
Manual Control
1
3
2
8
Inputting the External Trigger
To use manual control in Strobe Mode,
refer to items , , and under
and
.
8
Inputting the External Trigger
6
Manual Control
1
3
4
2
The Light Units are turned ON for
a set time after the external trigger
signal is input.
Photocoupler OFF
Photocoupler ON
Lit.
Not lit.
Not lit.
* When the Trigger Logic
Switch is set to HIGH
Continuous Mode
ON/OFF Mode
Strobe Mode
Front panel operation
External control using a PLC
or image process device
The Light Units are turned ON or
OFF according to the external
trigger signal input.
Photocoupler OFF
Photocoupler ON
Lit.
Not lit.
Not lit.
* When the Trigger Logic
Switch is set to HIGH
5
What You Can Achieve with This Control Unit
* It is possible to turn LED light unit ON and
OFF by Ethernet communications, too.
Locking Settings
When the setting switch is pressed for
2 seconds or longer, the lighting mode and
light intensity settings are locked, and
the LOCK setting indicator lights. (The set
values can be viewed.) Pressing the switch
again for 2 seconds or longer releases the lock.
2
Selecting the Channel
Press the channel selection switch to select the
channel to set (L1 to L3). The channel indicators
will change.
Press.
3
Setting the light Intensity
Press the setting switch to light the BRT setting
indicator.
Turn the setting switch to set a value between 0 and 255.
(Default setting: 255, Minimum: 000, Maximum: 255)
* The Light Units are light dimly at the minimum value.
Press.
Press for 2 s.
1
Setting the Manual/External Mode
Selector to Manual
Set the Manual/External Mode Selector to MANU
to set Manual Mode.
Make sure that the LOCK setting indicator is not light and that the trigger
logic switch is set to HIGH. Otherwise you may not be able to perform the
rest of this procedure.
Check
4
Selecting the Lighting Mode
Press the setting switch to light the PLS
setting indicator.
Turn the setting switch to select the lighting
mode from Continuous Mode, ON/OFF Mode,
or Strobe Mode.
(Default value: F00 )
Continuous Mode
Turn the setting switch and set F00 to
turn ON the Light Units continuously.
ON/OFF Mode
(If the external trigger is not used, the Light Units are ON continuously.)
Turn the setting switch and set F00 to turn the Light Units ON and OFF.
The Light Units are turned ON or OFF according to the external trigger signal input.
Strobe Mode
(If an external trigger is not used, the Light Units are OFF.)
To flash the strobe, turn the setting switch and
select a setting from F01 to F10
(strobe time of 40 μs to 40 ms).
The Light Units are turned ON for the period of time set
on the setting switch after the external trigger signal is input.
For details on the external trigger input, refer to 5. Inputting the External Trigger.
Digital Window
F00
F01 F02 F03 F04 F05 F06 F07 F08 F09 F10
40 μs 80μs 120 μs 200 μs 600 μs
Strobe Mode
1 ms 4 ms 10 ms 20 ms 40 ms
Continuous Mode
ON/OFF Mode
Status
Press.
Make sure that the main power source is turned ON.
Set items , , and when using Continuous Mode or ON/OFF Mode.
Set items , , , and when using Strobe Mode.
1
3
4
2
1
3
2
6
Manual Control
External trigger signal or Ethernet
communications setting can be selected when
using ON/OFF mode by external control.
To use external trigger signal in ON/OFF mode,
refer to items , , and under
7
Control with External Signals
8
Inputting the External Trigger
1
2
3
and
.
To use Ethernet communications setting in ON/OFF mode,
refer to items , , , and under
1
2
7
Control with External Signals
3
5
.