55
Locking Settings
When the setting switch is pressed for 2
seconds or longer, the lighting mode and
light intensity settings are locked, and the
LOCK setting indicator lights. (The set values
can be viewed.) Pressing the switch again for
2 seconds or longer releases the lock.
7
Manual Control
Check
Make sure that the LOCK setting indicator is
not light and that the trigger logic switch is
set to HIGH. Otherwise you may not be able
to perform the rest of this procedure.
Set the Manual/External Mode Selector to MANU
to set Manual Mode.
1
Setting the Manual/External Mode Selector to Manual
4
Selecting the Lighting Mode (Continued)
4
Selecting the Lighting Mode
Press the setting switch to light the PLS setting indicator.
Turn the setting switch to select the lighting mode from Continuous Mode,
ON/OFF Mode, or Strobe Mode. (Default value:
F00
)
Turn the setting switch and set
F00
to turn ON the Light Units continuously.
To flash the strobe, turn the setting switch and select a setting from
F01
to
F10
(strobe time of 40 μs to 40 ms). The Light Units are turned ON for the
period of time set on the setting switch after the external trigger signal is input.
The Strobe Mode can be set for 24V DC Light Units only.
Turn the setting switch and set
F00
to turn the Light Units ON and OFF.
The Light Units are turned ON or OFF according to the external trigger signal input.
40μs
80μs
120μs
200μs
600μs
Strobe Mode
(The Strobe Mode can be set
for 24V DC Light Units only.)
1ms
4ms
10ms
20ms
40ms
Continuous Mode / ON/OFF Mode
Status
Digital Window
F01
F02
F03
F04
F05
F06
F07
F08
F09
F10
F00
3
Setting the light Intensity
Press the setting switch to light the BRT setting indicator.
Turn the setting switch to set a value between 0 and 255.
(Default setting:
255
, Minimum:
000
, Maximum:
255
)
Connector Connection Example
Even if the Light Unit is disconnected, the
channel can be selected until the power is
turned OFF. (The settings are also retained.)
Precautions for Channel Selection
Press.
Press for 2 s.
Continuous Mode
ON/OFF Mode
(If the external trigger is not used, the Light Units are ON continuously.)
Strobe Mode
(If an external trigger is not used, the Light Units are OFF.)
For details on the external trigger input, refer to 9. Inputting the External Trigger.
Press.
Make sure that the main power source is turned ON.
Set items , , and when using Continuous Mode or ON/OFF Mode.
Set items , , , and when using Strobe Mode.
1
3
4
2
1
3
2
* The light intensities are theoretical values.
24V LIGHT
0.4
(Dimly lit)
0.8
1.2
99.6
100.0
…
Light intensity (%)
HLV LIGHT
0.0
(Not lit)
0.4
0.8
99.6
100.0
…
…
000
002
254
255
001
Digital Window
Eight channels from L1 to L8 are allocated to the 24V LIGHT and HLV
LIGHT output connectors. (The ELR-02V connector for 24V LIGHT is L1.)
When L1 is selected, settings for the L1 Light Unit for the 24V LIGHT connectors
(both SMP-03V-BC/ELR-02V) and the HLV LIGHT connectors can be changed.
The 8 channels can be controlled separately.
2
Selecting the Channel
Press.
Press.
Press the channel selection switch to select the channel to set (L1 to L8).
Press the channel selection switch , to select the Light Units in order from L1 to L8.
Press the channel selection switch , to select the Light Units in order from L8 to L1.
Only channels with Light Units connected to them can be selected.
(If a new Light Unit is connected, the lowest channel is automatically selected.)
Only channels with Light Units connected to them can be selected. If a Light Unit is removed
without turning OFF the power supply, the channel for the Light Unit that is no longer connected
may be selected. This does not indicate a malfunction. Check the following table for details.
There is risk of fire or electric shock. Make sure that the power supply is turned OFF when
you connect Light Units or Spotlights.
The channel with the
disconnected Light Unit
can be selected.
The Light Unit was disconnected
without turning OFF the power supply.
The channel with the
disconnected Light Unit
cannot be selected.
Operation
If there is an electrical connection,
the Light Unit will light.
(The channel can be selected.)
The Light Unit does not turn
ON or an HLV ID error occurs.
(The channel cannot be selected.)
A Light Unit that is not
supported was connected.
L1, L2, L4 and L5
Channels
can be selected for the following connections:
and
: L 1 , L 2 and L 4
: L1 and L5
.
L1, L2, L4, L5, L6, L7 and L8
Channels
can be selected if the connections are changed to the following:
and
: L5, L6, and L7
: L4 and L8