- 1 -
LDLB/LDLB-IP Series
Bar Lights
Instruction Guide
Thank you for purchasing a CCS product. To ensure proper use of
the product, please read this instruction guide before use and keep
it for your future reference.
These LED Light Units feature integrated light control and ON/OFF control circuits.
The LEDs are driven with a constant-current system and the light is set to any of 100 levels with variable-current control.
You can change between Constant Lighting Mode and Overdrive Mode.
You can manually set the light intensity from the operating panel or set it with an analog input (0 to 10 V) from an external device.
You can daisy-chain up to three Light Units to provide power and externally control the light intensity of all of the Light Units together.
The LDLB-IP Series provides IP67 water resistance.
Features
The following symbols indicate and classify the precautions in the
Instruction Guide.
PROHIBITED
DISASSEMBLY
PROHIBITED
DO NOT TOUCH
WITH WET HANDS
DO NOT SUBJECT
TO MOISTURE
MANDATORY
ACTIONS
These symbols indicate
prohibited actions.
This symbol indicates
required actions.
This product has been designed with full consideration of safety. However, incorrect usage of the product may result in
fire, electric shock, or other serious accidents. Observe the following precautions.
Warning
Indicates that incorrect
usage may result in
serious injury or death.
Caution
Indicates that incorrect
usage may result in injury
or property damage.
The following symbols are used in this Instruction Guide to indicate
and classify the relative importance of warnings and cautions.
Caution
Do not drop the product
or subject it to impact.
Doing so may cause the
product to malfunction.
PROHIBITED
Do not bundle product
cables with highvoltage
lines or power lines.
Doing so may cause the
product to malfunction.
Allow leeway between
t h e c a b l e s w h e n
installing them.
MANDATORY
ACTIONS
Be c aref ul of st atic
elec tr ic it y. Damage
to the LED light may
o c c u r, i f a p e r s o n
c h a r g e d w it h st at i c
electricity touches it.
Keep the product away
from all items charged
with static electricity.
PROHIBITED
B e f o r e m o v i n g t h e
product, disconnect
all connecting cables.
Damaging the cables
may result in fire or
electric shock.
MANDATORY
ACTIONS
Do not bend a cable
past its natural bending
radius or jam a cable
into a narrow space
w h e n w i r i n g t h e
product. Doing so may
cause product failure.
PROHIBITED
Always hold onto the
plug or connector when
d i s c o n n e c t i n g t h e
cables. Pulling on the
cable may damage the
cable and result in fire
or electric shock.
MANDATORY
ACTIONS
Do not intentionally
s h o r t - c i r c u i t t h e
positive and negative
output terminals.
PROHIBITED
If there is dust or other
foreign matter on the
electrodes, turn OFF
the power supply and
then use a dr y cloth
to remove the dust or
foreign matter. Failure to
do so may result in fire.
MANDATORY
ACTIONS
B e s u r e t o u s e t h e
p r o d u c t w i t h i n t h e
range of input voltage.
Applying the voltage
beyond the range may
cause product failure.
PROHIBITED
Do not wipe the product
with organic solvent s,
such as paint thinner or
benzene. Discoloration
or deterioration of the
product surfaces may
occur.
PROHIBITED
1
2
3
4
5
6
Important Information for Equipment Safety
Confirming Product Information
Names and Functions of Parts
Connections
Setting the Light Intensity on the Operating Panel
External Control of the Light Intensity
- Read Before Use -
Warning
Do not disassemble
or modify the product.
Doing so may result in
fire or electric shock.
DISASSEMBLY
PROHIBITED
LED light radiation may
cause corneal or retinal
abnormalities if you
look directly at the light.
To prevent harmful light
exposure, never look
directly at the LED light.
MANDATORY
ACTIONS
D o n o t c o n n e c t o r
disconnect the Light
Unit and cables with
wet hands. Doing so
may result in electric
shock.
DO NOT TOUCH
WITH WET HANDS
This product generates
high temperatures. Do
not touch the product
while it is turned on or
immediately after it is
turned off, or burning
m ay r e s u l t . P r ov i d e
cooling with a fan or
other ventilation if the
product is to be used in
a closed space.
MANDATORY
ACTIONS
Using LDLB- series
Light Units (not water
resistant)
M a k e s u r e t h a t t h e
product is free of moisture
or any liquid. Exposure to
water may result in fire,
electric shock.
DO NOT SUBJECT
TO MOISTURE
Connect or disconnect
the light cable only after
turning off the power
supply. Failure to do
so may result in circuit
damage, f ire caused
by a minute spark, or
electric shock.
MANDATORY
ACTIONS
If abnormal condition occurs such as fuming, heat, smell,
noise, or so on, stop using the product immediately, and
turn off the power supply. A fire or electric shock may
result if the product is kept used.
MANDATORY
ACTIONS
The following label is attached to the LED light. The color of the label indicates the luminescence color of the product. The name
label specifies the model name, power consumption, and serial number. Be sure to check the contents before using the product
and handle the label with care. If the label is missing or damaged and the contents cannot be checked, please contact CCS Inc.
Connecting One Light Unit
Daisy-chaining Two or Three Light Units
Maximum Cable Length
Before you connect the Input Cable or Link Cable, make sure that the power supply is turned OFF. Making connec-
tions with the power supply turned ON may result in fire, electric shock, or breakdown in the Light Unit.
Handle the Light Units and connectors with care. Do not deform or damage the connectors.
Connect the cables correctly to the Light Units.
Connect a Sealing Cap to any output connectors to which a cable is not connected to maintain water resistance. The
Sealing Cap is connected to the output connector when the Light Unit is shipped.
If the Light Unit is not used for a long period of time with the cable disconnected, attach the Cap to the connector or take
other measures to maintain water resistance.
Observe the following precautions to prevent electrical shock and accidents from water entry.
Using LDLB-IP-series Light Units
Warning
Caution
1
1
2
2
You can daisy-chain up to three Light Units to set the light intensities or turn ON and OFF all of the Light Units together.
The maximum length of the 24-VDC power supply cable depends on the wire diameter, operating mode, and number of con-
nected Light Units. The maximum cable lengths are given in the following table.
One Light Unit Connected: The table gives the maximum length of the Input Cable.
Two or Three Light Units Connected: The table gives the maximum total length of the Input Cable and Link Cables.
Connect the Input Cable to the input connector and connect the leads on the end of the Input
Cable to an external device.
Connect the output and input connectors of the Light Units with Link Cables. Also connect the Input
Cable to the input connector and connect the leads on the end of the Input Cable to an external device.
Turn ON the power supply.
Turn ON the power supply.
Changing from Constant Lighting Mode to Overdrive Mode
1) Set the ON/OFF inputs from the external device to the status for turning ON the Light Unit in Constant Lighting Mode.
Refer to
7. ON/OFF Inputs
for information on the ON/OFF input.
2) Change the operating modes in order from the Light Unit that is farthest from the power supply.
(In the above figure, the order would be Light Unit A, Light Unit B, and then Light Unit C.)
Refer to
3. Names and Functions of Parts
for information on changing the operating mode. If the setting status of the
ON/OFF inputs is not correct, an overdrive error will occur when you change the operating mode. Also, if the order is not
correct, an overload error will occur.
Changing from Overdrive Mode to Constant Lighting Mode
1) Change the operating modes in order from the Light Unit that is nearest to the power supply.
(In the above figure, the order would be Light Unit C, Light Unit B, and then Light Unit A.)
Refer to
3. Names and Functions of Parts
for information on changing the operating mode. If the order is not correct,
an overload error will occur. The setting status of the ON/OFF inputs is not relevant.
To external device
Input Cable
Link Cable
Link Cable
Light Unit A
Light Unit B
Light Unit C
Sealing Cap
(for LDLB-IP Series)
When you daisy-chain Light Units, you must use the operating panel on each Light Unit to change between Constant
Lighting Mode and Overdrive Mode. Use the following procedure to change the operating mode.
To external device
Input Cable
Sealing Cap
(for LDLB-IP Series)
Connection Example
LDLB Light Unit
External Circuit
Variable power supply
(0 to 10 VDC)
24 VDC
* You can adjust the light intensity with a variable power supply or a variable resistor.
*
If you use a variable power supply, use a power supply with a sinking
output of 3 mA minimum per Light Unit.
Pin 5
Pin 3
If you use a variable resistor, use the one specified below.
One Light Unit: 15 kΩ
Two Light Units: 10 kΩ
Three Light Units: 5 kΩ
Do not exceed an allowable difference of 20% in the overall resistance.
Note: According to product specifications, the light intensity that is set on
the operating panel may be used when the resistance is near the
maximum value.
If pin 5 (analog input) and pin 3 (common ground) are not connected on the input connector or if 13 to 24 V (maximum in-
put voltage: 26.4) is input, you can use the + and − switches on the operating panel to manually set the light intensity.
If 0 to 10 V is applied between pin 5 (analog input) and pin 3 (common ground) on the input connector, you can set the light
intensity to any of 100 levels with the voltage of the analog input.
The light intensity is displayed on the digital display between 00 and 99
(100 levels).
If you hold down the + or − key for more than 1 second, the value will
change faster.
The manually set light intensity is saved internally even after you turn
OFF the power supply or after you change to external light intensity
control with an analog input.
The light intensity is displayed on the digital display between 00 and 99 (100 levels).
To maintain the light intensity, continue to input a constant voltage. The light intensity that is set by the analog input is not
stored in the Light Unit.
Note: Depending on the number of connected Light Units and the cable length, different light intensities may be set for the same analog
input voltage.
Note: The digital display will show "--" if the light is turned OFF in Constant Lighting Mode. If you turn the light ON and OFF repeatedly over
a short period of time, the digital display may not display numbers correctly.
MODE
OverDrive
Continuous : Hold down
L
E
V
E
L
O/D
Con
Input Connector (M12 Plug) Configuration
Setting the Light Intensity with an Analog Input
Voltage (V) between Pin 5 and 3
Li
gh
t i
nt
en
si
ty
0
99
20
40
59
79
2
4
6
8
10
5
4
1
3
2
3
Set the operating modes of the Light Units.
Operating
Panel
Input Connector (M12 Plug)
The digital display shows the light in-
tensity between 00 and 99.
(“00” is the minimum light level.)
You can manually set the light intensity
with the + and
−
switches. Refer to
5.
Setting the Light Intensity on the Oper-
ating Panel
for details.
You can change the operating mode
by holding down the + and − switches
at the same time for 3 seconds.
This connector is used to supply
power to the Light Unit and to input
signals to control the light intensity
and turn the light ON and OFF.
Note: There are no restrictions in the installation
direction. You can install the Light Unit up-
side down or in any other direction. Refer to
10. Dimensions
for the installation holes.
Using LDLB-IP-series
Light Units
If you do not use this con-
nector, always attach a
Sealing Cap to it to main-
tain water resistance.
Output Connector (M12 Socket)
If you daisy-chain Light Units, this
connector is connected to the input
connector on the next Light Unit with
a Link Cable.
If you daisy-chain Light Units, you can
supply power, control the light intensity
with an analog input, and use an ON/
OFF input to control all of the Light Units
together. You can also control the light
intensity of the Light Units individually
from the operating panels. You can con-
nect up to three Light Units.
A Link Cable (model: FECB-0.6-M12-
5M-5F, 0.6 m) is available as an option
(sold separately).
The LDLB-IP-series Light Units maintain IP67
water resistance when this Cable is connected.
Input Cables (models: FECB-M12-5F
Series, 1, 2, 3, and 5 m, flying leads) are
available as options (sold separately).
The LDLB-IP-series Light Units maintain IP67
water resistance when this Cable is connected.
Light-emitting Surface
Digital Display
Mode Indicator
(Top panel)
Pin
No.
Signal
Cable
FECB-M12-
5F Series
Wire color
1
24 VDC
Brown
2
ON/OFF input (NPN)
White
3
Common ground
Blue
4
ON/OFF input (PNP)
Black
5
Analog input (0 to 10 V)
Gray
Pin
No.
Signal
Cable
FECB-M12-
5F Series
Wire color
1
24 VDC
Brown
2
ON/OFF input (NPN)
White
3
Common ground
Blue
4
ON/OFF input (PNP)
Black
5
Analog input (0 to 10 V)
Gray
Light intensity
00
01
…
49
50
…
98
99
Radiant
quantity
Constant Lighting Mode 10%
11%
…
55%
55%
…
99% 100%
Overdrive Mode
100% 102%
…
214% 216%
…
328% 330%
5
5
4
3
1
2
3
4
2
1
Refer to
9. Optional Products (Sold Sep-
arately)
for details on the Link Cable.
Refer to
6. External Control of the
Light Intensity
for information on the
analog input.
Refer to
7. ON/OFF Inputs
for informa-
tion on the ON/OFF inputs.
Refer to
9. Optional Products (Sold Sepa-
rately)
for details on the Input Cable.
Label (Example)
Name label (Example)
The general relationship between the light intensity and the radiant quantity is shown in the following table.
Constant Lighting Mode
You can set the light intensity to any of
100 levels from the operating panel or with
an analog input from the input connector.
You can turn the light ON and OFF with an
ON/OFF input from the input connector.
Overdrive Mode
The mode indicator on the operating
panel will light. A larger current en-
ables a brighter light intensity (100 lev-
els) than in Constant Lighting Mode.
However, the light intensities that you
can set are restricted as shown below.
Refer to
7. ON/OFF Inputs
for details.
Operating time
Signal repeat period to light the LEDs
Wire diameter
Number of Light Units connected in Constant Lighting Mode
Number of Light Units connected in Overdrive Mode
1
2
3
1
2
3
AWG16
10 m
10 m
10 m
10 m
5.5 m
2 m
AWG18
10 m
10 m
10 m
8 m
3.5 m
1.5 m
AWG20
10 m
10 m
7 m
5.5 m
2 m
Cannot be used.
AWG22
10 m
7 m
4.5 m*
3 m*
1 m*
Cannot be used.*
* The wire diameter is AWG22 for the optional (sold separately) FECB-M12-5F-series Input Cables and FECB-0.6-M12-5M-5F Link Cable. If the
maximum length given above is exceeded, shorten the Input Cable or contact CCS.
− switch
+ switch
Digital display