Technicalinst. guide
Limpido XC2
v4.0
The calculated production time is (in hours): (Pool temperature - Minimum temperature*) + 1.
*The minimum temperature (15°C by default), can be configured. The calculated production time
can therefore be influenced.
There will be no production below this minimum temperature.
Default calculated production time (minimum temperature = 15°C);
Pool water
temperature
10
15
20
25
30
35
Production
time in AU-
TO mode
0h
1h
6h
11h
16h
21h
Production time calculated using a minimum temperature = 12°C;
Pool water
temperature
10
15
20
25
30
35
Production
time in AU-
TO mode
0h
4h
9h
14h
19h
24h
However, it is not recommended to lower the minimum temperature below 12°C in order to protect
the electrolysis cell plates from low temperature operation, as this would reduce their service life.
If production time seems insufficient, make sure the pool volume is set to the maximum in order
to optimise chlorine production (see 6.3.4), then, if necessary, use the ON mode (24h/24h) or the
PROG mode (by entering the required number of hours in "Prog hours". (see 6.3.5)
www.c-
cei.fr
5