background image

ENGLISH                                                                                                            
 

 

Rev1_23/03/21                                                                   Attached HERIONOVA_User_Manual_08/05/2019 

13 

 

6.

 

Switch on 

 Switch off 

 

 

The lamp is not equipped with an 
independent switch on-switch off 
system.  

 

The  lamp  will  switch  on  when 
plugged-in  and  switch  off  when 
the power is off. 
 

7.

 

Problem solving 

 

In case the lamp doesn’t turn on:

 

 

Check  that  the  lamp  is  properly 
wired to the supply voltage. 

 

Check  that  polarity  wiring  has 
been carried out correctly. 

 
 

Please  contact  CCEA’

S  Technical  support 

service in case the lamp is defective  

 

CCEA Technical Support Service 

Phone: +39 0444 572083 

[email protected]

 

www.ccealights.com

 

 

 

8.

 

Replacing  the  Led  light 

source 

The  outstanding  lifetime  of  the  LED 
light  source,  over  60.000  hours, 
makes  it  unnecessary  to  replace  the 
PCB  LED  if  the  lamp  is  properly 
installed  and  used  following  the 
instructions  in  this  manual.  Please 
contact  CCEA

’s

  Technical  Support 

service - or your Reseller 

 in case the 

replacement  of  the  PCB  LED  is 
needed  for  any  defects  not  covered 
by the warranty.  

 

9.

 

Product  maintenance  and 
cleaning 

 

 

 

 
Switch  off  power  the  supply  before 
any  installation,  maintenance  or 
reparation procedures. 

 
This product is maintenance-free. 
 
 

 

Lamp  cleaning  to  be  carried  out 
only  after  it  has  been  switched 
off  and  surfaces  have  cooled 
down. 

 

Carefully  rinse  the  lamp  surface 
with  a  mild  cleanser  and  then 
wipe  off  using  a  soft  cloth  in 
order to avoid scoring it. 

 
 
 
 

All  material  damages  caused  by 
liquid  leakage  may  damage  the 
lamp. 

 

In  case  the  lamp  is  working  in 
environments where lubricants or 
coolers  are  present,  all  cleaning 
operations  should  be  carried  out 
at the end of the working cycle.  

  
 
 

   

WARNING

 

 

NOTICE

 

 

Содержание HERIONOVA Series

Страница 1: ...1 ENGLISH HERIONOVA Series Installation Manual E506617 LOW VOLTAGE LUMINAIRE...

Страница 2: ...nting accessories 8 4 3 Installation 9 5 Plug in 11 5 1 Low voltage plug in with M12 connector 11 5 2 Power cord 12 5 3 Integrated Power Cord 12 6 Switch on Switch off 13 7 Problem solving 13 8 Light...

Страница 3: ...mechanical vibrations and processing shavings IP 67 degree of protection lamp Plug in to 24VDC Four lengths available Use only with class 2 power supply Suitable for wet location For cabinet use only...

Страница 4: ...se Installation and use of the product is recommended only provided it is in perfect conditions and the user is well acquainted with all safety instructions CCEA the manufacturer waives any responsibi...

Страница 5: ...ht source as it may cause a temporary reduction of vision Irritation aches damages or accidents may as well occur Avoid staring directly at the light source The device must be adjusted so as to avoid...

Страница 6: ...ns for any issues Any product tampering or modifications not having been approved by the manufacturer will null and void the warranty 2 3 Damage risk levels Dangers where noncompliance may immediately...

Страница 7: ...e the codes and see if you can identify the same model on the table hereunder The code printed on the brand name label shows the device s week and year of production Note Do not discard the product la...

Страница 8: ...02 Rear Swivel Arm Mounting accessories 45 HNFX01 SIDE KIT BRACKET Model L1 in mm HN0221S02 HN0221S03 369mm 14 53in HN0321S02 HN0321S03 498mm 19 6in HN0521S02 HN0321S03 756mm 29 76in HN0721S02 HN0721S...

Страница 9: ...To have the lamp correctly mounted without damaging the sealing gaskets the lamp has to be fixed to the machine structure with the HNFX01 side mounting brackets locked on the lamp Hook the two side b...

Страница 10: ...ons of the fastening holes on the installation surface See the sizes table on page 8 HNFX01 for the drilling center lines Fasten the swivel mounting bracket to the lamp by tightening the screws at the...

Страница 11: ...h M12 connector Wrong wiring may cause damages to the lamp All electrical connections have to be carried out by qualified electricians Please respect the polarity of connectors Always use the power co...

Страница 12: ...RIPTION Cod M12TFC5 M12 A 4 poles 60VDC connector female with UL PVC Cable 3G1 5mmq Cross section Product code includes the above PIN Conductor 1 DC 24VDC black 1 2 Not connected 3 DC 0VDC black 2 4 N...

Страница 13: ...cessary to replace the PCB LED if the lamp is properly installed and used following the instructions in this manual Please contact CCEA s Technical Support service or your Reseller in case the replace...

Страница 14: ...ed out following different ways Any unauthorized repairs or attempts to repair the product Equipment operation under environmental conditions other than those specified in the user manual Liquid leaka...

Страница 15: ...E Please refer to the data printed on the label or engraved on the lamp Power supply 22 36VDC Power input 26 5 40 66 5 93W see label IEC Class III Degree of protection IP67 Compatible WITH NEMA 6 LED...

Страница 16: ...lass III device Degree of protection IP67 UL 2108 STANDARD FOR LOW VOLTAGE LIGHTING SYSTEM Edition 2 Revision Date 2017 05 30 CSA C22 2 NO 9 0 96 LUMINAIRES Edition 1 Revision Date 1998 07 01 Reaff 20...

Страница 17: ...purpose luminaries CEI EN 62031 LED modules for general lighting Safety specifications CEI EN 62384 DC or AC supplied electronic control gear for LED modules Performance requirements This is a standa...

Отзывы: