Once  the  right  position  is  found, 
tighten both screws 
 

 
 
 
 
 
 
 
 
 
 
ATTENTION! When side mounting the 
lamp  ensure  to  never  completely 
loosen  the  M6  screws  allowing  for 
lamp  rotation,  to  avoid  having  the 
lamp fall down. 
 

 

Proceed  in  connecting  the  lamp 
to a power source 

 

Correct installation using HNFX02 

The item HNFX02 is made of: 
-

 

N.1 painted swivel bracket 

-

 

N.4 M5x16 screws 

-

 

N.4  squared  nuts  supplied  with 
the lamp  

 

 

Mark  out  the  positions  of  the 
fastening holes on the installation 
surface.  See  the  sizes  table  on 
page  8  (HNFX01)  for  the  drilling 
center lines. 

 

Fasten  the  swivel  mounting 
bracket to the lamp by tightening 
the screws at the four sliding nuts 
in  the  two  lanes  on  the  back  of 
the lamp. 
 
 

 
 
 

 

 
 

 

Fix  the  lamp  to  the  structure 
(pict.7). Use M5 screws. 
 
 

 
 
 

  
 
 

 
 

 

You 

can 

adjust 

the 

lamp 

inclination  by  unscrewing  the  2 
M5  screws  of  the  base  (see 
picture 

below). 

Once 

the 

inclination  defined,  tighten  the 
screws (pict.8 and 9). 

 

 
 
 
 
 
 
 
 
 
 
 
 

NOTICE

 

Collegamento elettrico 

Picture 06 

NOTICE

 

 

Damaged or broken lamp. 

 

The brackets as well as the screws 
tightening have to be checked on a 
regular basis. 

Picture 07 

Picture 08 

Picture 09 

Содержание HERIONOVA Series

Страница 1: ...1 ENGLISH HERIONOVA Series Installation Manual E506617 LOW VOLTAGE LUMINAIRE...

Страница 2: ...nting accessories 8 4 3 Installation 9 5 Plug in 11 5 1 Low voltage plug in with M12 connector 11 5 2 Power cord 12 5 3 Integrated Power Cord 12 6 Switch on Switch off 13 7 Problem solving 13 8 Light...

Страница 3: ...mechanical vibrations and processing shavings IP 67 degree of protection lamp Plug in to 24VDC Four lengths available Use only with class 2 power supply Suitable for wet location For cabinet use only...

Страница 4: ...se Installation and use of the product is recommended only provided it is in perfect conditions and the user is well acquainted with all safety instructions CCEA the manufacturer waives any responsibi...

Страница 5: ...ht source as it may cause a temporary reduction of vision Irritation aches damages or accidents may as well occur Avoid staring directly at the light source The device must be adjusted so as to avoid...

Страница 6: ...ns for any issues Any product tampering or modifications not having been approved by the manufacturer will null and void the warranty 2 3 Damage risk levels Dangers where noncompliance may immediately...

Страница 7: ...e the codes and see if you can identify the same model on the table hereunder The code printed on the brand name label shows the device s week and year of production Note Do not discard the product la...

Страница 8: ...02 Rear Swivel Arm Mounting accessories 45 HNFX01 SIDE KIT BRACKET Model L1 in mm HN0221S02 HN0221S03 369mm 14 53in HN0321S02 HN0321S03 498mm 19 6in HN0521S02 HN0321S03 756mm 29 76in HN0721S02 HN0721S...

Страница 9: ...To have the lamp correctly mounted without damaging the sealing gaskets the lamp has to be fixed to the machine structure with the HNFX01 side mounting brackets locked on the lamp Hook the two side b...

Страница 10: ...ons of the fastening holes on the installation surface See the sizes table on page 8 HNFX01 for the drilling center lines Fasten the swivel mounting bracket to the lamp by tightening the screws at the...

Страница 11: ...h M12 connector Wrong wiring may cause damages to the lamp All electrical connections have to be carried out by qualified electricians Please respect the polarity of connectors Always use the power co...

Страница 12: ...RIPTION Cod M12TFC5 M12 A 4 poles 60VDC connector female with UL PVC Cable 3G1 5mmq Cross section Product code includes the above PIN Conductor 1 DC 24VDC black 1 2 Not connected 3 DC 0VDC black 2 4 N...

Страница 13: ...cessary to replace the PCB LED if the lamp is properly installed and used following the instructions in this manual Please contact CCEA s Technical Support service or your Reseller in case the replace...

Страница 14: ...ed out following different ways Any unauthorized repairs or attempts to repair the product Equipment operation under environmental conditions other than those specified in the user manual Liquid leaka...

Страница 15: ...E Please refer to the data printed on the label or engraved on the lamp Power supply 22 36VDC Power input 26 5 40 66 5 93W see label IEC Class III Degree of protection IP67 Compatible WITH NEMA 6 LED...

Страница 16: ...lass III device Degree of protection IP67 UL 2108 STANDARD FOR LOW VOLTAGE LIGHTING SYSTEM Edition 2 Revision Date 2017 05 30 CSA C22 2 NO 9 0 96 LUMINAIRES Edition 1 Revision Date 1998 07 01 Reaff 20...

Страница 17: ...purpose luminaries CEI EN 62031 LED modules for general lighting Safety specifications CEI EN 62384 DC or AC supplied electronic control gear for LED modules Performance requirements This is a standa...

Отзывы: