2.0 Safety Information
ALWAYS connect the control cable to the actuator BEFORE
installing the Chicken Switch®.
2.1 Finger Pinch Points
NEVER place your fingers in the area where the actuator
extends when the control station is connected to the
actuator. The actuator could pinch your hand/fingers
against something nearby.
Also, keep fingers clear of the bottom of the actuator near
the magnets when the actuator is near a ferrous surface.
2.2 Strong Magnets
The holding magnets are very strong. Keep magnetically-
sensitive objects such as watches or computer disks away
from the bottom of the actuator.
3.0 Battery Requirements
• Eight (8) AA alkaline cells are required. Carefully observe
polarity when installing cells.
• Only Alkaline batteries should be used.
3.1 Battery Life
• A set of fresh alkaline cells should give hundreds of
operations.
3.2 Battery Replacement
• ALWAYS disconnect the control cable before replacing
batteries to avoid possible static damage of the
electronics!
• Turn the control station upside down, remove the
endplate retaining knob. Remove the endplate and slide
the cover out as shown below.
3.3 To connect/Disconnect Batteries:
3.4 CAUTION: Static Discharge Potential
• To avoid possible damage to electronic components
disconnect the control cable before replacing batteries.
4.0 Operation
ALWAYS connect the control cable to the actuator BEFORE
installing the Chicken Switch®.
4.1 Connecting the Control Cable:
1. Align the arrow on the cable end with the top of the
receptacle.
2. Push in and engage the threads on the coupling nut
and turn clockwise.
3. After one or two turns of the coupling nut, push in on the
cable end. Repeat this until the connector is fully seated.
4. Use a similar technique of turn-stop-and-pull to
disengage the cable ends.
TO AVOID POSSIBLE DAMAGE TO
ELECTRONIC COMPONENTS DISCONNECT
CONTROL CABLE BEFORE REPLACING
BATTERIES.
WARNING