CB Tech WaterBox Скачать руководство пользователя страница 5

Page 

of 

20 

 

 

I.

 

Scope 

The  CB  Tech  WaterBox™  is  designed  to  remove  bacteria,  viruses,  cysts  and  other 
contaminants  from  natural  water  sources  such  as  surface  waters  (lakes,  rivers,  etc.) 

and  groundwater.  This  manual  describes  how  to  install  filter  cartridges,  start  the 
system, monitor and maintain the system and how to shut it down. It is important that 

the user is familiar with the entire contents of this manual to ensure that the CB Tech 
WaterBox™ is operated safely and properly. 

 

II.

 

Principle of Operation 

 

The  CB  Tech  WaterBox™  filtration  system  creates  clean  drinking  water  exceeding 

potable  water  standards.  The  CB  Tech  Nanomesh™  filters  employ  a  combination  of 
adsorption  and  size  exclusion  to  remove  microbial  pathogens  and  reduce  chemical 

contaminants from the  input water stream.  Water is cleaned as it passes through the 

filters; no chemicals, UV light, or heat are necessary. 

 

The CB Tech WaterBox™ has been tested by NSF International and received a letter of 

compliance  from  the  United  States  Public  Health  Command  certifying  it  has  met  the 
straight requirements of protocol 248. The CB Tech Waterbox removes over 99.9999% 

of  bacteria,  99.99%  of  viruses,  and  99.9%  of  cysts.  Additionally,  the  CB  Tech 

Nanomesh™ filter media used in the CB Tech WaterBox™ has been shown to remove or 
reduce a variety of other biological and chemical contaminants (see Appendix A). 

 

The CB Tech Nanomesh™ Stage I filters are specifically designed for removing organic 
compounds  and  suspended  solids  from  source  water.  When  properly  monitored  and 

maintained,  they  protect  the  CB  Tech  Nanomesh™  Stage  II  filter  and  extend  its 
operational life. 

 

III.

 

List of Symbols and Abbreviations 

 

o

F – Degrees Fahrenheit 

cm - Centimeter 

o

C – Degrees Celsius 

kg – Kilogram 

gpm – Gallons per minute 

GFI – Ground fault interrupter 

lbs – Pounds 

psi – Pounds per square inch 

A – Amps 

in – inch(es) 

VDC – Voltage - direct current 
VAC – Voltage - alternating current 

ft – foot/feet 

Содержание WaterBox

Страница 1: ...e 1 of 20 CB Tech WaterBox Mobile Water Filtration System Operation Manual CB Tech Tel 866 622 9373 7251 Cathedral Rock Drive www CarbonBlockTech com Las Vegas NV 89128 sale CarbonBlockTech com 01411...

Страница 2: ...PLUG TO AC POWER CABLE CONNECT GFI PLUG TO POWER SOURCE PRESS TEST BUTTON TO VERIFY GFI FUNCTION THEN PRESS RESET CONNECT 12V 24V DC POWER CABLE ATTACH POWER CABLE TO BATTERY OR USE 12 VDC CIGARETTE L...

Страница 3: ...BOTH WATER INTAKES ARE FREE FROM OBSTRUCTION 3 CHECK ALL HOSE CONNECTIONS BETWEEN PUMP AND WATER SOURCE FOR LEAKS APPLY PETROL GEL TO O RINGS IF NECESSARY 4 CONFIRM PUMP INLET STRAINER IS CLEAR OF DEB...

Страница 4: ...ns 5 IV Technical Specifications 6 V System Overview 7 VI Using the CB Tech WaterBox Filtration System 8 A Unpacking 8 B Power Connections 9 C Operating the CB Tech WaterBox 11 D Maintaining the CB Te...

Страница 5: ...ght or heat are necessary The CB Tech WaterBox has been tested by NSF International and received a letter of compliance from the United States Public Health Command certifying it has met the straight...

Страница 6: ...cm x 60 2 cm x 33 3 cm Electrical requirements Voltage 12 24 VDC or 120 230 VAC Maximum height above water Priming 8 ft 2 4 m Operating 20 ft 6 1 m Safe to run pump dry Yes Temperature range Dry Stora...

Страница 7: ...er Outlet Port 16 230 VAC GFI Plug 5 Filter Housing Wrench 17 120 VAC GFI Plug 6 Pressure Gauge 18 Component Storage Bag 7 Pump Intake Strainer 19 Hose Intake Adaptor 8 Pump 20 Hose Intake Float 9 Vol...

Страница 8: ...is has the following parts 25 of 3 8 wire reinforced intake hose 10 of 3 8 wire reinforced outlet hose 2 CB Tech Nanomesh Stage II filter cartridge 1installed 1 spare 5 CB Tech Nanomesh Stage I filter...

Страница 9: ...lti voltage power supply Figure 2 contains two voltage converters one for switching 120 VAC 230 VAC to 12 VDC and other for switching 24 VDC to 12 VDC Only one voltage converter operates at a time dep...

Страница 10: ...lug from receptacle and allowing protective cap to close CAUTION Verify power source voltage prior to the connection with the multi voltage power supply only Figure 2 DC Power cable connection connect...

Страница 11: ...epeated every time the power source is disconnected to verify GFI functionality and reduce the possibility of electrical shock hazards for users CAUTION Although the CB Tech WaterBox is fitted with GF...

Страница 12: ...confirm that the pump intake strainer is in place and free of debris Figure 6 The pump intake strainer must be in place when operating the CB Tech WaterBox to prevent debris from entering the pump and...

Страница 13: ...lter housing 1 This information will be needed to decide when the filters need to be changed OPERATIONAL NOTES It is normal to observe a small amount of black powder in the filtrate during the initial...

Страница 14: ...water at ground level 6 Turn on the WaterBox press the pressure relief valve on the first Stage I filter housing to purge the air and allow the line to be primed All air must be purged from the line...

Страница 15: ...Figure 9 c Insert cartridge in the housing with the two O rings toward the top The cartridge should seat itself easily in the filter housing assembly d Rinse any particulate debris out of the filter...

Страница 16: ...decreases by 10 psi below the initial starting pressure Therefore it is important to make a note of the initial pressure reading on the system pressure gauge A typical initial pressure reading should...

Страница 17: ...continues to trip confirm that the power source is operating at the selected voltage 12 VDC 24 VDC 115 VAC or 230 VAC If the power source is operating correctly and the circuit breaker continues to tr...

Страница 18: ...e outlet hose and water intake are free from obstruction Confirm that pump inlet strainer is clear of debris If clogged unscrew cap remove and wash mesh screen Check all plumbing connections for leaks...

Страница 19: ...AAs Organophosphates pesticides and herbicides Total Organic Carbon TOC Volatile Organic Compounds VOCs Customer Feedback Detailed feedback from users in the field on the performance of the CB Tech Wa...

Страница 20: ...ed or error free or that non material defects will be corrected This warranty does not apply to any defect caused by failure of the user to provide a suitable operating environment use of products for...

Отзывы: