Cavli Wireless C100QM/C10QM Hardware Manual
84
Power) is not less than 100 W.
✧
The protective device PCB layout should be as close as possible to the “V” shaped line
to avoid the “T”
shaped line.
✧
The ground plane around the module guarantees integrity and should not be split.
✧
ESD control of the surrounding environment and operators needs to be taken into
account during module production, assembly and laboratory testing.
Table 5-4 C100QM/C10QM ESD Features
Test port
Contact discharge Air discharge
unit
USB interface
±4
±8
KV
USIM interface
±4
±8
KV
Analog voice interface
±4
±8
KV
VBAT power supply
±4
±8
KV
5.6 Reliability index
Table 5-5 C100QM/C10QM Reliability Test
Test items
Test Conditions
Guideline
Test Results
Low
temperatur
e work
Temperature:
–
40oC
Working mode: normal
work
Test duration: 24 h
IEC60068-2-1
Visual inspection: normal
Function check: normal
RF
indicator
check:
normal
High
temperatur
e work
Temperature: 85oC
Working mode: normal
work
Test duration: 24 h
JESD22-A108-
C
Visual inspection: normal
Function check: normal
RF
indicator
check:
normal
Temperatur
e cycle
High temperature: 85oC
Low temperature:
–
40oC
Working mode: normal
JESD22-A105-
B
Visual inspection: normal
Function check: normal
RF
indicator
check: