6.2 Diesel Engine Service
The diesel engine requires routine maintenance. Oil must be checked and
changed regularly. Oil, air and fuel filters must be checked and changed
regularly. The engine crankcase and oil filter hold 3.5 gal. (13.2 L) of SAE 10W30
or 15W40 viscosity lubricating oil. For detailed information on these routine
maintenance requirements as well as other service recommendations, see the
engine manufacturer’s literature found in the
APPENDIX
.
6.3 Pump Service
The high pressure water pump requires minimal maintenance. The pump oil
should be checked on a regular basis. The pump crankcase holds 4.2 gal. (16.0
L) of SAE 30 (ISO-68) viscosity non-detergent lubricating oil. See pump
manufacturer’s literature found in the
APPENDIX
for further information.
6.4 Inspection/Cleaning of water inlet strainer
The CaviBlaster 2570-D is equipped with a water strainer located between the
water feed pump and the pressure pump. To inspect and clean the strainer,
follow the procedure below:
1)
Isolate or disconnect the water source from the inlet connection to the
power unit.
2)
Unscrew the filter housing (turn CCW).
3)
Pull filter bowl down.
4)
Remove the strainer.
5)
Inspect the strainer and flush any debris with clean water.
6)
Rinse any debris out of filter bowl.
7)
Push strainer back into housing.
8)
Push the bowl back onto filter housing.
9)
Thread the housing CW by hand to tighten.
Page - 27
CaviBlaster 2570-D Operations Manual
For more information please email [email protected] or call 1-(352)275-5319