Shutting down the CaviBlaster
®
power unit:
1. Adjust engine RPM to “MIN” (Figure # 16).
2. Shut off the engine by turning the key to the “
OFF
” position (Figure # 13).
3. Stop the feed pump by moving the feed pump switch to the “OFF” position (Figure # 12).
4.
Squeeze the gun trigger to the open or “ON” position (Figure # 15) to release the water
pressure remaining in the hose(s)
while the gun is submerged
.
5. It is now safe to remove the gun from the water.
6. Flush the system and rinse the power unit with fresh water at the end of the day.
Maintenance of the CaviBlaster
unit:
1. Empty and clean the inline strainer every day. (Figure # 1)
2. Check the oil level and consistency in the engine and pressure pump every day. (Figures # 2, 3)
3. Flush the system and rinse the power unit with fresh water after each days use,
for at least 5 minutes, to make sure all inside residuals are removed.
4. Inspect the gear box oil level, and change it after the first month or 20 hours and every six months
or 100 hours thereafter.
5. Change the engine oil after the first month or 20 hours and every six months or 100
hours thereafter. Replace the oil filter every 200 hours. Use SAE 10W-30 oil for general
all- temperature use.
6. Clean the air cleaner cover, filter elements and base every three months or 50 hours. Replace
the paper filter element every twelve months or 300 hours or if damaged or excessively dirty.
7. Change the oil in the pressure pump after the first 50 hours and every 500 hours thereafter.
Use single-weight lubricating oil (SAE 30 weight non-detergent)
8. Change the spring for the gun trigger every 12 months or less if required.
Summarizing the operating instructions:
Page -
11
CaviBlaster 1325-GSS Operations Manual
For More information please email [email protected] or call 1-(352)275-5319