5.0 OPERATION
The CaviBlaster
®
3040-D should be operated by two (2) properly trained individuals. One,
the diver, operates the zero-thrust gun, while the other operates the power unit. Both
operators should be in audio or visual communication with each other.
The CaviBlaster
®
3040-D Should Only Be Operated By
Properly Trained Personnel Who Are Familiar With
The Contents Of The Manual. Review The Safety
Requirements Found In Section 3 Before Operating.
5.1 Preparing the CaviBlaster
®
for Operation
The following checklist should be completed in advance of operation, so that the unit is
always ready for immediate use. This should be completed after each use.
1)
1.- Inspect the CaviBlaster
®
power unit, hoses, JIC fittings and gun for any signs of damage.
2)
2.- Inspect the inline strainer and filter cartridges to ensure that they are not clogged (See Figure 6.1).
Clean or change cartridge(s) if necessary.
3)
3.-
Check for proper engine oil level (See engine Owner’s Manual found in the
Appendix
). Add
lubricating oil (SAE 10W40) if necessary.
4)
4.-
Check for proper pressure pump oil level (See pump Owner’s Manual found in the
Appendix
). Add
lubricating oil (SAE 30 non-detergent) if necessary.
5)
5.- Check fuel tank (See Figure 2.1) for proper diesel fuel level. Add diesel fuel (ASTM Grade No. 1-
D or 2-D, or EN 590) if necessary.
Incorrect Fuels Should Not Be Used As They
May Prove Hazardous And Cause Damage
To The Engine.