3
The feed hose has the feed pump on one end (Figure 8) and a cam-lock socket on the other
end (Figure 7). Insert the electrical plug powering the feed pump into the waterproof
electrical outlet on the end of the power unit cart under the handle (Figure 9). Ensure that the
knob on the plug is facing up and mates with the notch in the outlet cover.
If the plug is
engaged upside down, the pump will turn in reverse.
Ensure that the feed hose is connected
to the pressure pump, the feed pump is submerged in water, and the wiring splice is kept dry
prior to starting the feed pump.
Either fresh water or seawater can be used with this system.
Note: The feed pump has had a neoprene check valve installed in the discharge. This valve will prevent water
from draining out of the feed hose through the feed pump when the pump is turned off. However, this check
valve somewhat restricts the flow of water from the pump. If maximum water flow is required from the feed
pump (for example, if the power unit is situated more than 12 feet above the water source) the check valve and
stainless retaining washer can be removed from the pump discharge by removing the black hose barb fitting.
Figure 7
Figure 8
When feeding the CaviBlaster
®
with an alternate water source,
the source must supply water
at a volume of greater than 12 gallons per minute at a maximum pressure of 70-psi
. Connect
the water source to the inlet of the pressure pump (Figure 10).
Ensure that the feed hose is
connected to the pressure pump and the water is on prior to starting the pressure pump.
Figure 9
Figure 10