36
9M02-8978-A002-EN
Version 14
Safe-E-
Stop™
User Guide
8.3.2 MSD LCD
The MSD LCD gives guidance to the current operational state as detailed in
The LCD display also provides additional information when using the five-button cluster to the left.
The MSD LCD remains illuminated.
# represents the PSD sub-address
8.4 MSD Operational States
Table 13: MSD Operational States
SIDE STATUS
LED
SIDE COMM
LOSS LED
SIDE ESTOP
LED
SIDE ERROR
LED
DISPLAY
MSD INACTIVE STATE
No PSDs linked
Orange
LINKED PSD
NONE
Any PSD Linking
Orange
Green
LINKING
#
Flashing
MSD ACTIVE STATE
PSDs linked
(normal mode)
Green
LINKED PSD # # # # #
ESTOP pressed
Red
Red
ESTOP # # # # #
Low RF signal
Red
Orange flashing
PSD (with low signal) #
blinking
COMM LOSS longer
than 30 seconds
Red
Red
Red
CL RESET MSD
ERROR
Red
8.5 MSD Information and Setup
The MSD LCD display in combination with the five pushbuttons to the left allow access to three different
screens plus the bootup screen that shows the current firmware revision, you can cycle around the
screens by using the up down buttons on the MSD, the screens are;
▪
The default status screen, See the table above.
▪
The Ethernet/IP Address Setting screen, see the next section.
▪
The RF Received Signal Strength Indication (RSSI) screen; this shows the signal strength of
each PSD that is currently linked, a lower number (around 50-60) indicates a very strong signal
and a higher number (around 90-100) shows a weaker signal.
8.5.1 IP Address
IP Address Setting method is clarified as follows:
To set Dynamic Address Selection (DHCP); Set all DIP switches to ‘0’. To set a Static IP address the
following process should be followed;
▪
Unlink and turn off all PSDs
▪
Re-boot the MSD by removing and re-applying power.
▪
The MSD has a partly variable IP address (192.168.1.X).