5.4
Switched Outputs
The controller has switched outputs that are turned on under certain conditions to perform a function. The
outputs turn on to +Battery voltage to drive the load when active. The following items are the available functions
for switched outputs.
WARNING
SWITCHED OUTPUTS HAVE A FLOATING VOLTAGE OF APPROXIMATELY 8 V WHEN OFF. IF
USING THE OUTPUTS FOR DIGITAL LOGIC, IT WILL BE NECESSARY TO PUT A PULL-DOWN
RESISTOR (2.2 K
Ω, 1 WATT) FROM THE OUTPUT TO GROUND TO ENSURE A LOW LOGIC
LEVEL WHEN OUTPUT IS OFF.
AVERTISSEMENT
LES SORTIES COMMUTEES PRESENTENT UNE TENSION FLOTTANTE D'ENVIRON 8 V
LORSQU'ELLES SONT OFF (INACTIVES). SI VOUS SOUHAITEZ UTILISER LES SORTIES
COMME SIGNAUX LOGIQUES NUMERIQUES, IL FAUT INSTALLER UNE RESISTANCE PULL-
DOWN (2,2 K
Ω, 1 W) ENTRE LA SORTIE CONCERNEE ET LA MASSE, POUR ASSURER UN
NIVEAU LOGIQUE BAS QUAND LA SORTIE EST OFF.
Default Settings
Switched Output
Default Setting
Switched Output A
Fuel Output
Switched Output B
Disable
Switched Output C
Crank Output
Switched Output D
Disable
Switched Output E
Disable
Switched Output F
Disable
Event Functions
Name
Active Mode
Description
Fuel
Cranking, Running
Active during cranking and running to supply fuel to engine.
Crank
Cranking
Active during cranking to start the engine.
Pull Coil
Cranking
section for more information.
LCD Backlight
Global
Active when LCD Backlight is active.
Voltage Regulator
Running
Active when engine is starting/running and is not in Idle
Mode.
ETS (Energize to
Stop)
ETS Timer
Active during Energize to Stop timer. See
for more details.
!
!
Содержание DYNAGEN TOUGH Series TE410
Страница 1: ...TOUGH SeriesTM TE410 User Manual ...
Страница 14: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 14 9M02 9249 A001 EN Revision A 2 3 Wiring Harness ...
Страница 15: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 15 9M02 9249 A001 EN Revision A 2 4 Typical Wiring Diagram ...
Страница 22: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 22 9M02 9249 A001 EN Revision A CT Wiring ...
Страница 24: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 24 9M02 9249 A001 EN Revision A ...
Страница 28: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 28 9M02 9249 A001 EN Revision A ...