background image

-2-

e

Area Patio Heater

INSTRUCTION MANUAL

WARNINGS

PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION AND USE.

•  This appliance must be used outdoors or in a well 

ventilated area, and should not be installed or used 

indoors. 

•  Change the gas cylinder in a well ventilated area, 

away from any inflammation sources.

•  The cylinder must be stored outdoors or in a well 

ventilated area.

•  Storage this appliance indoors is permissible only if 

gas cylinder is disconnected and removed from the 

appliance.

•  Do not move this appliance when in operation, or 

after it has been turned off before the temperature 

has cooled down.

•  Do not attempt to alter the appliance in any man-

ner. Do not paint the radiant screen, control panel 

or reflector.

•  Do not obstruct the ventilation holes of the cylin-

der housing.

•  The appliance must be installed and gas cylinder 

stored in accordance with local gas fitting regula

-

tions. 

• 

Shut off the valve at the gas cylinder or the regula

-

tor before moving the appliance.

• 

Use only the type of gas specified by the manufac

-

turer.

• 

Repairs should be done by a qualified person.

•  In case of violent wind, particular attention must be 

taken against tilting of the appliance.

• 

Check that the regulator seal is correctly fitted and 

able to fulfil its function.

•  Close the gas supply at the valve of the gas cylinder 

or the regulator after use.

•  Do not use this appliance until all connections have 

been leak tested.

•  In the event of gas leakage, the appliance shall not 

be used or if alight, the gas supply shall be shut off 

and the appliance shall be investigated and recti-

fied before it is used again.

• 

Checking the tubing or the flexible hose per month 

and each time the cylinder is changed.

• 

The tubing or the flexible hose must be changed 

within the prescribed intervals or within one year. 

•  The hose assembly must be replaced prior to the 

appliance being put into operation if there is evi-

dence of excessive abrasion or wear, or if the hose 

is damaged, and that the replacement hose assem-

bly shall be that specified by the manufacturer.

•  The heater should be inspected before use and at 

least annually by a qualified service person. More 

frequent cleaning may be required as necessary. 

It is imperative that control compartment, burners 

and circulating air passageways of the appliance be 

kept clean. 

• 

Shut off and check heater immediately if any of the 

following conditions exist: 

• 

The smell of gas in conjunction with extreme yel

-

low tipping of the burner flames.

•  Heater does not reach a proper temperature. A 

temperature less than 5℃ will cause restricted heat 

flow and the appliance will not work properly. 

•  The appliance starts making popping noises during 

use (a slight popping noise is normal when the 

appliance is extinguished).

•  The regulator & hose assembly must be located 

out of pathways where people may trip over it or in 

area where the hose will not be subject to acciden-

tal damage.

•  Any guard or other protective device removed for 

servicing the heater must be replaced before oper-

ating the heater.

•  Children and adults should be warned of the haz-

ards of high surface temperatures and should stay 

away to avoid burns or clothing ignition. 

•  Young children and pets should be carefully super-

vised when they are in the area of the heater. 

• 

Clothing or other flammable materials should not 

be hung from the appliance, or placed on or near 

the appliance.

•  Do not place articles on or against this appliance. 

Certain material or items when stored under or 

near this appliance will be subjected to radiant 

heat and could be seriously damaged.

• 

Do not use or store flammable materials near this 

appliance. 

•  Do not spray aerosols in the vicinity of this appli-

ance while it is in operation. 

•  Always maintain at least 0.9m clearance from com-

bustible materials.

• 

Always position the appliance on a firm level 

surface. An amply ventilated area must have a min-

imum of 25% of the surface area open. The surface 

area is the sum of the walls surface.

Содержание SILVERINO

Страница 1: ...SILVERINO item 13 936 e Patio Heater c Plynov z i s Plynov iari...

Страница 2: ...peration if there is evi dence of excessive abrasion or wear or if the hose is damaged and that the replacement hose assem bly shall be that specified by the manufacturer The heater should be inspecte...

Страница 3: ...er assembly Step 3 Connecting hose and regulator if supplied to the burner assembly Put gas cylinder on the base and connecting regulator to a gas cylinder then assembly 2 cylinder belts and ensure ga...

Страница 4: ...ition The gas cylinder must always be used in an upright position Close the heater control knob by turning fully clockwise Close the gas cylinder tap and then attach the regulator onto the gas cylinde...

Страница 5: ...ce Respect the minimum clearances from combus tible materials GAS LEAKAGE TEST NEVER USE A NAKED FLAME TO CHECK FOR LEAKS NEVER LEAK TEST WHILE SMOKING The gas connections on this appliance are leak t...

Страница 6: ...sembly dry at all times If the gas control is exposed to water in any way DO NOT try to use it It must be replaced Airflow must be unobstructed Keep controls burner and circulation air passageways cle...

Страница 7: ...Gas cylinder low or empty Igniter fails Use match to light pilot and obtain new igniter and replace See below pictures Pilot won t stay lit Dirt build up around pilot Clean dirt from around pilot Con...

Страница 8: ...open The surface area is the sum of the walls surface Product Name Area Patio Heater Country Code CH ES FR GB GR IE IT PT BE CY CZ DK EE FI GR IT LT LV MT NL NO SE SI SK BG RO TR AT CH DE CZ FR GB GR...

Страница 9: ...vystaveni p i vysok teplot zejm na pop lenin a z n t Je zak z no v et oble en a tak um s ovat jin ho lav nebo v bu n kapaliny a materi ly v bl zkosti topidla Je zak z no prov d t jak koliv pravy na to...

Страница 10: ...i roubujte jej pomoc 5 ks roub a podlo ek M5 10 Upozorn n Pro spr vn zav r n dve p izvedn te jednou rukou horn st s ho kem a a pot dot hn te v ech 5 roub Krok 3 P ipojte k ho ku hadici s reduk n m ve...

Страница 11: ...m st mimo otev en pla men nebo jin zdroj zap len P esn pokyny k pou it plynov lahve z sk te od sv ho dodavatele plynu Plynov l hev mus b t v dy pou v na p epravov na i skladov na ve svisl poloze P ed...

Страница 12: ...ho kem na sv m m st Respektujte minim ln vzd lenosti od ho lav ch materi l ZKOU KA T SNOSTI Nikdy nepou vejte ohe p i zkou ce t snos ti Nikdy neku te p i zkou ce t snosti Plynov p pojky p stroje jsou...

Страница 13: ...lo k ucp n vzduchov ho otvoru Na vstupuje pro p ipojen k ventilu opat en p evle nou matic W 21 8 x 1 14 L a na v stupu hadicovou koncovkou pro hadici na PB s vnit n sv tlost 8mm nebo z vitem G 1 4 L T...

Страница 14: ...ada e v poloze PILOT nechejte odvzdu nit alespo 2 minuty nebo dokud neuc t te plyn Mal tlak plynu Plynov l hev je pr zdn Selh n zapalov n Pro zap len pou ijte sirky Ho k zhas n Ne istoty okolo PILOT h...

Страница 15: ...0 I3P 37 I3P 50 Velikost trysky 1 64mm 1 64mm 1 55m 1 64mm 1 60mm Tepeln v kon 11kW 11kW 13 5kW 11kW 12 5kW Spot eba plynu 0 8kg h 0 8kg h 0 9kg h 0 8kg h 0 9kg h Model H1109B V robce Ningbo Innopower...

Страница 16: ...V robek je v souladu s n e uveden mi p edpisy Sm rnice Evropsk ho parlamentu a Rady 2016 426 ES a normami EN 14543 2005 A1 2007 Certifik t 0063CO7365 0063 19 V robce Ningbo Innopower Hengda Metal Prod...

Страница 17: ...kej teplote najm pop len n a z palov Je zak zan ve a oble enie a tie umiest ova in hor av alebo v bu n kvapaliny a materi ly v bl zkosti vykurovacieho telesa Je zak zan vykon va ak ko vek pravy na ohr...

Страница 18: ...jte ho pomocou 5 ks skru tiek a podlo iek M5 10 Upozornenie Pre spr vne zatv ranie dver pridvihnite jednou rukou horn as s hor kom a a potom dotiahnite v etk ch 5 skrutiek Krok 3 Pripojte k hor ku had...

Страница 19: ...imo otvoren plame alebo in zdroj zap lenia Presn pokyny na pou itie plynovej f a e z skate od svojho dod vate a plynu Plynov f a a mus by v dy pou van prepravuje aj skladovan vo zvislej polohe Pred pr...

Страница 20: ...hor kom na svojom mieste Re pektujte minim lnej vzdialenosti od hor a v ch materi lov SK KA TESNOSTI Nikdy nepou vajte ohe pri sk ke tesnosti Nikdy nefaj ite pri sk ke tesnosti Plynov pr pojky pr str...

Страница 21: ...duchov ho otvoru Na vstupuje na pripojenie k ventilu opatren prevle nou maticou W 21 8 x 1 14 L a na v stupe hadicovou koncovkou pre hadicu na PB s vn tornou svetlos ou 8mm alebo z vitom G 1 4 L Techn...

Страница 22: ...he PILOT nechajte odvzdu ni aspo 2 min ty alebo k m nepoc tite plyn Mal tlak plynu Plynov f a a je pr zdna Vynech vania zapalovania Pre zap lenie pou ite z palky Hor k zhas na Ne istoty okolo PILOT ho...

Страница 23: ...P 37 I3P 50 Ve kos trysky 1 64mm 1 64mm 1 55m 1 64mm 1 60mm Tepeln v kon 11kW 11kW 13 5kW 11kW 12 5kW Spotreba plynu 0 8kg h 0 8kg h 0 9kg h 0 8kg h 0 9kg h Model H1109B V robca Ningbo Innopower Hengd...

Страница 24: ...V robok je v s lad s n ie uveden mi predpismi Smernica Eur pskeho parlamentu a Rady 2016 426 ES a normami EN 14543 2005 A1 2007 Certifik t 0063CO7365 V robca Ningbo Innopower Hengda Metal Products Co...