background image

Содержание NWRF Nixie

Страница 1: ...NWRF Nixie Watch User Manual...

Страница 2: ...2 Copyright C 2010 Cathode Corner All rights reserved Printed in USA Watch made in USA...

Страница 3: ...3 Table of Contents Introduction 5 Warranty 7 Operating Instructions 9 Maintenance 12...

Страница 4: ...4...

Страница 5: ...wer supply and setting controls are all visible The watch features 12 or 24 hour time display mode user settable tilt angle and easy time setting operation The timekeeping rate is adjustable and the w...

Страница 6: ...5mm diameter x 1 8mm thick mineral glass Strap width 20mm between lugs Battery life Approximately 4 6 months at 50 viewings per day Replaceable Parts Battery CR2 lithium non rechargeable 3 Volt 750mA...

Страница 7: ...n postage to the customer The software programmed into the microprocessor in the watch is licensed under the General Public License and carries NO WARRANTY WHATSOEVER including merchantability and fit...

Страница 8: ...8...

Страница 9: ...nd slips into position Be careful not to disturb the black adjustment capacitor to the left of the lower end of the battery The spring is rather strong to keep the battery from losing contact when the...

Страница 10: ...ours To increment the hours press the Adv button repeatedly until the proper hour is displayed Press Set to set the tens of minutes The watch displays the current minutes with the left digit blinking...

Страница 11: ...are displayed first then the minutes then finally an incrementing seconds display if held at the viewing angle It may take some practice to get the watch to display the time every time you tilt it to...

Страница 12: ...other everyday liquid events However the seal is not sufficient to protect the watch against submersion in water If it should be submerged remove it from water right away unscrew the cover and check...

Страница 13: ...from the watch case as described below First unscrew the cover Remove the battery Unscrew the two socket head screws using a 050 1 3mm hex key One screw is located between the bases of the two tubes a...

Страница 14: ...straight Then pull the spacer off the tube and set it aside The two pairs of pins nearest the back of the tube often have trouble entering the socket unless they are bent just a little bit towards th...

Страница 15: ...gned with the other tube and pressing it down into place on the foam pad After the tube s have been replaced the module may be reinstalled in the case Drop the module into the case and align the two s...

Страница 16: ...16 Cathode Corner 2602 E Helen Tucson AZ 85716 USA www cathodecorner com...