SERVICE MANUAL
67102 PLUNGER PUMP
SERVICING THE 67102 PLUNGER PUMP SERIES
Do not service pump or electrical equipment while energized.
Electricity can cause personal injury, death or property damage.
1. Adhere to “Lock Out” and “Tag Out” procedures for electrical equipment.
2. Before commencing pump service, turn power supply off.
3. Keep water away from electrical outlets and electrical devices.
4. Electrical components must be installed by a qualified
electrician to avoid risk of electrocution.
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the user to read and understand all instructions, important safeguards, and safety precautions before operating or
servicing any pump. Failure to do so may result in property damage, personal injury or death.
General Safety Information and Symbols
Pay special attention to the following signal words, safety alert symbols and statements:
indicates a hazardous situation which, if not avoided, will result in death or serious injury.
indicates a hazardous situation which, if not avoided, could result in death or serious injury.
indicates a hazardous situation which, if not avoided, could result in minor or moderate injury or property damage.
indicates a hazardous situation which, if not avoided, could result in property damage.
Indicates a potential personal injury hazard. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING
WARNING
CAUTION
NOTICE
DANGER
PUMP
MODEL
FLOW
PRESSURE
RPM
TEMPERATURE
SHAFT DIA.
OIL CAPACITY
gpm
lpm
psi
bar
Pump
Motor
˚F
˚C
in
mm
oz
l
67102
100.0
378.5
1,000
69
680
—
140
60
1.772
45
320
9.46
67102C
100.0
378.5
1,000
69
680
—
140
60
1.772
45
320
9.46
Содержание 67102