SERVICE MANUAL | 3570 Series Plunger Pumps
15
(763) 780-5440 | [email protected] | www.catpumps.com
Servicing the Seals
MANIFOLD AND SEAL INSTALLATION
1.62 Install backup rings, then O-rings into the
large grooves on the end of the V-packing
cylinders.
1.63 Install the O-rings into the smaller grooves on
the other end of the V-packing spacers.
1.64 Install the coil springs into the V-packing
cylinders.
1.67 Install the second V-packings with the
grooved sides also facing down.
1.68 Install the female adapters with grooved sides
facing down into the V-packing cylinders.
1.69 Install V-packing spacer with the smaller
diameter sides facing down and press them
into place.
1.65 Install the male adapters into the V-packing
cylinders with the flat sides facing down.
NOTICE: There are two O-rings for each
V-packing cylinder. The thicker O-ring goes in
the larger groove with the backup ring.
1.66 One side of the V-packing has a groove. Install
the first V-packings with the grooved sides
facing down and press them into place.