![CAT Pumps 1XP Series Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/cat-pumps/1xp-series/1xp-series_installation-operational-and-repair-manual_2573333011.webp)
11
5.7 Place 1/2" open wrench behind cam
(8) onto motor shaft. Position tips of
spanner-wrench into two holes of
cam and turn to loosen.
5.14 Use a pick tool to remove slinger o-ring
(11) from motor flange.
5.13 Use a pick tool to remove motor flange
o-ring (12) from motor flange.
5.12 Remove and inspect shaft seal (10)
from motor flange. Do not scratch or
damage motor shaft surface.
5.10 Remove and inspect shaft seal (10)
from motor flange. Do not scratch or
damage motor shaft surface.
5.9 Insert two (2) flat tip screw drivers
between flange and pry shaft seal
away from motor.
5.8 Unthread threaded cam from motor
shaft
For Threaded Shaft Units:
If old shaft seal cannot be
removed, it may require removing
motor cover.
(See Service Bulletin 002)
NOTICE
5.11
Old Shaft Seal
New Shaft Seal