background image

SERVICING THE UNLOADER AND REGULATOR

1DX015ELS.MIST, 1DX03ELS.MIST - Integral Regulator
2DX, 3DX, 3DNX, 3SPX - Integral Unloader
2DX.MIST - Integral Regulator
3SP - 7700 Modular Unloader (refer to individual data sheet)

Disassembly

NOTE: On models 3SP30G1I, 3SP35G1I, 3SPX30G1I
and 3SPX35GEI remove black adjusting handle.

1.

Remove brass adjusting cap by turning in a counterclock-
wise direction.

2.

Remove exposed coil spring and flat spring retainer.

3.

Use an M19 wrench to remove piston retainer by turning
in a counterclockwise direction.

NOTE: The piston stem and valve assembly may fall out
when the piston retainer is removed. If so, proceed to step
6., if not, continue with step 4.

4.

Use a needle nose pliers to remove piston stem and valve
assembly.

5.

Separate piston stem from valve. Secure the valve near
the valve retainer. Insert a screwdriver into slotted head of
piston stem and unthread from valve.

CAUTION: Exercise extreme caution to avoid contact and
damage to the tapered surface of valve.

6.

Examine seat at the bottom of the unloader chamber for
grooves, pitting or wear, replace only as needed.

CAUTION: Seat will be damaged when removed.

Reassembly

1.

If seat is worn or damaged, press new seat into unloader
chamber until squarely seated.

2.

Examine piston stem, washer, valve retainer and valve for
grooves, pitting or wear and replace as needed. Examine
o-rings and back-up ring for cuts or wear and replace as
needed.

3.

Lubricate and install o-ring over slotted head of piston
stem, then position back-up ring on top of o-ring.

4.

Lubricate and install o-rings on valve retainer.

5.

Install washer and then valve retainer with o-rings onto
piston stem. Apply Loctite® 242® to threads of piston
stem and screw valve onto piston stem.

6.

Lower complete piston stem and valve assembly into
unloader chamber with valve facing downward.

7.

Examine piston retainer for damaged threads or wear and
replace as needed. Examine o-ring for cuts or wear and
replace as needed.

8.

Apply Loctite® 242® to threads and then hand thread piston
retainer into unloader by turning in a clockwise direction,
and then tighten with wrench.

9.

Examine spring retainer and coil spring for fatigue or
breaks and replace as needed.

10. Place spring retainer into piston retainer, followed by coil

spring.

11. Thread brass adjusting cap onto piston retainer by turning

in a clockwise direction.

Loctite and 242 are registered trademarks of Henkel Corporation.

Содержание 1DX Series

Страница 1: ... for adjusting pressure regulating devices and also for proper sizing of the nozzle or restricting orifice The pump is rated for a maximum pressure this is the pressure that is read at the discharge manifold of the pump NOT AT THE GUN OR NOZZLE Use PTFE thread tape or pipe thread sealant sparingly to connect accessories or plumbing Exercise caution not to wrap tape beyond the last thread to avoid ...

Страница 2: ...g retainer and press the backside of valve until seat separates from the spring retainer 6 Remove o ring from each seat and valve plug Reassembly 1 Examine spring retainers for internal wear or breaks in the structure and replace as needed 2 Examine springs for fatigue or breaks and replace as needed 3 Examine valves and seats for grooves pitting or wear and replace as needed 4 Examine seat and va...

Страница 3: ...n be easily removed from each seal chamber by hand or with reverse pliers Models 3DNX 3SP and 3SPX Remove V Packing and male adapter from each seal chamber by hand or with a reverse pliers Reassembly 1 Examine the manifold chamber walls for scale buildup or damage 2 Examine Hi Pressure seals or V Packings for frayed edges or uneven wear and replace as needed 3 Examine seal case o rings for cuts or...

Страница 4: ...plungers for scoring scale buildup chips or cracks and replace as needed The ceramic plungers do not need to be replaced with every seal servicing 6 Slide plunger retainer with seal washer into flat end of ceramic plunger 7 Apply Loctite 242 to exposed threaded end of plunger retainer 8 Install ceramic plunger with plunger retainer and seal washer over each plunger rod shoulder and thread hand tig...

Страница 5: ...t will be damaged when removed Reassembly 1 If seat is worn or damaged press new seat into unloader chamber until squarely seated 2 Examine piston stem washer valve retainer and valve for grooves pitting or wear and replace as needed Examine o rings and back up ring for cuts or wear and replace as needed 3 Lubricate and install o ring over slotted head of piston stem then position back up ring on ...

Страница 6: ...ssure is 60 PSI 4 BAR After prolonged storage pump should be rotated by hand and purged of air to facilitate priming Disconnect the discharge port and allow liquid to pass through pump and measure flow INLET ACCESSORIES are designed to protect against over pressuriza tion control inlet flow contamination or temperature and provide ease of servicing A shut off valve is recommended to facilitate mai...

Страница 7: ...34 10 4 6 220 52 16 7 1 8 300 80 25 10 2 10 450 120 38 14 3 15 900 250 80 30 7 20 1600 400 121 50 12 25 650 200 76 19 30 250 96 24 40 410 162 42 50 600 235 62 60 370 93 At a fixed flow rate with a given size hose the pressure drop across a given hose length will be directly proportional A 50 ft hose will exhibit one half the pressure drop of a 100 ft hose Above values shown are valid at all pressu...

Страница 8: ...tall new valve kit Pulsation Faulty Pulsation Dampener Check precharge If low recharge or install a new dampener Foreign material trapped in inlet discharge valves Clean inlet discharge valves or install new valve kit Water leak Under the manifold Worn V Packing Hi Pressure or Lo Pressure Seals Install new seal kit Increase frequency of service Worn adapter o rings Install new o rings Into the cra...