GB
15
4. REGULATION AND OPERATION
The appliance is designed to heat
rooms. Some parts of this product can
become very hot and cause burns. Par-
ticular attention has to be given where
children and vulnerable people are
present.
.HHS© FRPEXVWLEOH© RU© ¾DPPDEOH© PDWHULDOV© RU© SUHV
-
VXUH© YHVVHOV© HJ© VSUD\© FDQV© ½UH© H[WLQJXLVKHUV© DW©
least 50 cm from the appliance. Do not vaporise any
type of substance on the surface of the appliance.
Never touch the appliance with wet or damp hands
or feet. Do not wet the electronic control unit with
ZDWHU© RU© RWKHU© ¾XLGV© ,I© WKLV© RFFXUV© GLVFRQQHFW© WKH©
appliance from the mains power supply and allow to
dry completely.
When the appliance is installed at high altitude, the
air will be hotter than the set temperature.
:KHQ©\RX©WXUQ©WKH©DSSOLDQFH©RQ©IRU©WKH©½UVW©WLPH©LW©LV©
normal for it to give off a smell which disappears rap-
idly. You are recommend to ventilate the room after
XVLQJ©WKH©DSSOLDQFH©IRU©WKH©½UVW©WLPH
In cold conditions, the radiator may emit metallic
sounds when turned on. This is due to the expansion
of the materials.
Possible traces of oil noted on the bottom of the ra-
GLDWRU© GXULQJ© PRXQWLQJ© RU© WKH© ½UVW© WLPHV© \RX© WXUQ©
the appliance on may be left from the fabrication
process. Clean the part with proper precautions at
intervals of a couple of days. If the problem reoccurs,
follow the instructions in Chapter 7.
3.2 ELECTRICAL CONNECTIONS
WARNING
To be installed by a specialised engineer in accor-
dance with the applicable standards in the country
concerned.
When the appliance is installed, make sure the po-
wer is off and the mains switch is in the “O“ position.
The appliance requires a 230 V ~ 50 Hz power sup-
ply. Make sure the power line is appropriate for the
data given in table 1.
0DNH©VXUH©WKH©½[HG©SRZHU©OLQH©LV©½WWHG©ZLWK©D©GLV
-
connecting switch allowing the appliance to be dis-
connected completely from the household mains,
included the Pilot Wire, when present, in accord-
ance with the wiring rules.
If the appliance is installed in a bathroom, the
SRZHU©OLQH©PXVW©EH©½WWHG©ZLWK©D©©P$©5&'©KLJK©
sensitivity residual current protection device).
The power supply line and Pilot Wire control unit
must be protected by the same RCD.
Permanently connected appliances must be con-
nected using a connector block placed within a
proper junction box.
When installing the appliance in damp rooms
(kitchen, bathroom), the point of connection with
the household mains must be at least 25 cm from
WKH©¾RRU
5HVSHFW©WKH©ZLULQJ©GLDJUDP©LQ©½JXUH©©VFUXSXORXVO\
If the Pilot Wire is not connected to the pro-
gramming unit, it must be terminated and insu-
lated. Under no circumstances should the Pilot
Wire be connected to the earth.
Make sure the power cable cannot in any way come
into contact with the surface of the appliance (Fig. 6).
Fig. 8
Appliance cable
PHASE = BROWN
PHASE
NEUTRAL = GREY
NEUTRAL
PILOT WIRE = BLACK
Household mains
Two possible cases
Case 1: installation
without Pilot Wire
Case 2: installation
with Pilot Wire
Terminate and insulate
the wire
Connect to the Pilot Wire control unit or
transmission box
Содержание CVE0610F
Страница 68: ...xVExxxxF V Cod 5725011372 03 21 ...