background image

 

Page 9

 

 

A and B Frequency Weighting, SW2 
  

This is a two way switch which selects the required frequency weighting. The 
switch  must  be  switched  right  for  “A”  weighting  and  left  for  “B”  weighting. 
Figure 5.1 shows the “A” and “B” frequency weighting characteristics. 

 
 
Trip Level, SW3 
  

This  switch  is  used  to  set  the  trip  level  from  75dB  to  112.5dB  in  2.5dB 
increments.  
 
 

Warning Level, SW4 
  

This  switch  is  a  four  way  slide  switch  selects  when  the  warning  beacon  will 
switch on. The level is relative to the trip level and may give a warning –3, -6, -
9, or –12dB down from the trip level. 
  
 
The  following  tables show  the  switch  position  against  trip  level,  and  warning 
levels. 
  
 
 
 
 
 
 
 

Содержание Electronic Orange GA904

Страница 1: ...www castlegroup co uk Operating Manual Electronic Orange GA904...

Страница 2: ...ics itself If you would like to become a competent person in the eyes of the law then you may like to know more about our Competent Persons training course for Noise at Work Regulations You can visit...

Страница 3: ...Do not allow any conductive objects such as wire or metal particles to enter the unit Do not try to disassemble the instrument or attempt any repairs as this will invalidate your warranty Take a note...

Страница 4: ...4 Wiring to the Orange Beacon 5 Auxiliary Contact Wiring 5 Power Wiring to the GA904 5 AC DC Power Output Wiring 6 Controls 7 Operating Modes 7 Displays 8 Calibration and Set UP 8 Calibration RV1 8 Tr...

Страница 5: ...ntertainment Noise Controller in 1971 since then it has become an industry standard recommended by many Local Authority Environmental Health Officers The GA904 has been developed from the original Noi...

Страница 6: ...ause of a cut off is clearly indicated by the Level Microphone and External indicators Installation WARNING THE GA904 SHOULD BE WIRED TO THE MAINS POWER SUPPLY BY A QUALIFIED ELECTRICAL INSTALLATION E...

Страница 7: ...by Castle Group Ltd with each switch Duplicates are not kept by or available from Castle Group Ltd f Microphone mounting clip g Padlock for added security NB Two keys are supplied by Castle Group Ltd...

Страница 8: ...ver a club bar where shouting customers or applause could be unrepresentative of the overall sound level in the room The microphone should be mounted on a vibration free mounting such as the microphon...

Страница 9: ...act feature is not used The link should be removed if a door switch is used Power Wiring to the GA904 No additional items are required if the control box can be conveniently wired into the mains circu...

Страница 10: ...Wiring These signals are available for connecting chart recorders tape recorders or external displays etc The connections are as follows J10 1 12 J10 2 0V J10 3 12V J10 4 AC Output J10 5 DC Output J10...

Страница 11: ...lay This delay time is user adjustable between 1 to 10 seconds When the power is restored a mute function prevents the unit from a further trip for 20 seconds from the beginning of the trip period Thi...

Страница 12: ...ge The beacon will warn the operators when the trip level is approached Calibration and Set Up Although the GA904 will have been calibrated at the factory before despatch it may need slight adjustment...

Страница 13: ...uency weighting characteristics Trip Level SW3 This switch is used to set the trip level from 75dB to 112 5dB in 2 5dB increments Warning Level SW4 This switch is a four way slide switch selects when...

Страница 14: ...O 80 X X O X 82 5 X X O O 85 X O X X 87 5 X O X O 90 X O O X 92 5 X O O O 95 O X X X 97 5 O X X O 100 O X O X 102 5 O X O O 105 O O X X 107 5 O O X O 110 O O O X 112 5 O O 0 0 O Open Up X Closed Down...

Страница 15: ...Page 11 PCB Identification The diagram below shows the position of the following components on the PCB...

Страница 16: ...ad OPERATING MODE Manual When tripped unit must be manually reset Auto When tripped unit automatically resets after trip time Override Power output is maintained even during trip condition Manual Auto...

Страница 17: ...0 10m Microphone Cable 01ZL1011 20 20m Microphone Cable 01ZL1011 30 30m Microphone Cable 01MK376PXLR Microphone assembly for GA904 70MIS01730 Microphone Stand 01MC1 Microphone Clip 70MIS01510 Plastic...

Страница 18: ...nd International Standards An annual calibration is recommended to ensure that these high standards are maintained This is particularly important for cases in which instrument readings are to be used...

Страница 19: ...disposal of your product To find the nearest UK waste recycling point in your area enter your postcode in the website www recycle more co uk For more information please contact your local authority th...

Отзывы: