Underground Scissor Lift QJY3.2-1
11
The main switch is used as emergency switch. In case of emergency turn it to position OFF.
Main switch in position OFF: Power supply is interrupted
Main switch in position ON: Lift is ready for operation
POWER SWITCH
Turn on the POWER SWITCH to position ON, lift is ready for operation.
Up button
Once any button is actuated, the lift moves until the button is released or the limit position is reached.
DOWN button
Lift stops once switch is released. During lowering cycles the platform automatically stop at
a height above the bottom position.
LOCK button
Press the LOCK button to place the lifting load on the mechanical locking device for releasing loading
pressure of hydraulic system before service operation.
8.3 Operation
8.3.1
Preparations
8.3.2
1
Fully lower the lift.
2
Slowly position vehicle midway between platforms. Apply the parking brakes.
3
Position pads under vehicle manufacturers recommended lift points.
4
Leave vehicle and remain clear of lift.
5
If heights of two platforms, of primary or secondary lift, are not in a even level, make
adjustion.
Always lift the vehicle on the platforms.
8.3.2
Raising
During raising and lowering cycles: Closely watch the vehicle and the lift, do not
allow anyone to stay in lift area and make sure the vehicle doors are closed.