16.Fault detection
Vulnerability
Cause
Help
The Stage rotates only in the
one page or not at all.
Faulty switch
Replace
Damaged belt
Replace
Engine malfunction
Check cables or cables:
Replace the engine if it is
damaged.
The problem with lowering and lifting
the jaws, jamming on the Stage.
Leakage from the air system
Check all parts of the air
system
Cylinder not working
Replace the cylinder
piston.
Worn jaws
Replace jaws
Destroyed cylinder handle
washers
Replace
The head touches the rim during the
operation.
The clamping plate is incorrectly
fitted or is inadequate
Replace or adjust.
Loose screws of the handle, the
plate must not tighten
Tighten the screws,
replace the plate.
The rim deferment arm and clamping
jaw do not return to their initial
position.
Faulty pedal spring
Replace
Tilting the rim works faulty.
Clogged silencer .
Clean or replace.
Faulty rim dust collector cylinder
gasket.
Replace
Vulnerability
The switch holder is not movable
Cause
1)
It is not connected to an air source
2)
Damage to the air duct prevents free air flow
3)
The valve has been damaged
Help
1)
Connect the air source while maintaining the required pressure;
2)
Check the air edivion, replace the damaged wire and the joints;
3) Contact the service.