Door handle adjustment 

 

The door handle has a sophisticated adjustment system. The door handle 
comprises of only 4 parts and can be adjusted very simply by the end user. 
The system allows adjustment without the need for spanners or other tools. 
The stove is provided with a set screw to perform this function, keep this safe. 

The door rope over time will flatten and the door seal will start to let air into the 
stove, this will allow unwanted air into the combustion and increase the speed 
of the burn and controllability of the stove. 

Using the supplied Allen key, insert it into the hole in the side in the side of 
door containing the set screw. Turning the anti-clockwise slacken the set screw 
until the door handle becomes loose, once loose turn the handle the correct 
way as per below drawing below, on completion slowly re-tighten the setscrew 
until the handle is set. 

 

 

 

 

 

 

Flue test point 
 

Your Norvik stove has a flue test point, the function of the test point has 
various functions. 

  Correct instillation, aiding the installer to set up the Norvik with the flue 

pull matching the manufacturers recommendations 

  Measuring the flue pull to check for soot or tar build up in the chimney 

Flue test position 
 

Your Norvik stove test point is situated discreetly at the rear right hand side of 
the stove. The M8 screw is removed and a flue test meter is placed in the hole 
to measure the flue pull. On completion the M8 screw is re-fitted. 

 

 

 

 

 

 

 

 

 

Insert Allen key 

Flue test point 

Содержание NORVIK 5

Страница 1: ...ittent use and is tested and manufactured as a closed multi fuel appliance Cast Tec recommend that this appliance is installed by a HETAS registered Installation engineer or competent person Failure t...

Страница 2: ...Lighting the fire Firebox linings and baffle Running temperatures Cleaning Maintenance Woodburning tips theory INSTALLATION INSTRUCTIONS Building regulations Positioning clearances Chimney Flue connec...

Страница 3: ...ing this time as airing the room will allow this to disappear Step 1 Open the air control fully using the tool Glove Step 2 Place rolled up crumpled newspaper at the back of the stove Place small tind...

Страница 4: ...r containing the set screw Turning the anti clockwise slacken the set screw until the door handle becomes loose once loose turn the handle the correct way as per below drawing below on completion slow...

Страница 5: ...Fully close the air control and keep the stove door closed Move any combustibles away from the stove and chimney Check any other rooms that the chimney passes through and move and combustibles away fr...

Страница 6: ...make sure there is no build up of deposits that will restrict the exit of the flue gases Note The stove must not be modified in any way Any changes will invalidate your warranty Any replacement parts...

Страница 7: ...t be used in the same room as the appliance unless adequate additional ventilation is provided Other heating appliances requiring air for combustion shall not be used in the same room as the appliance...

Страница 8: ...d on the clearance figures shown in figure and reference should be made to building regulations and any rules in force at the time of installation Chimney Requirements An existing chimney or a new flu...

Страница 9: ...ket to support the flue The 5 125mm flue pipe required from the stove to the register plate Operational Problems Blackened Glass The wood is too damp Only use wood that has been stored for at least 12...

Страница 10: ...NOR INS REV 5 Nov 2017 Stove Dimensions...

Страница 11: ...l Customer name and address Installer Name Registration Number Date Who certifies that this installation is safe has been demonstrated to the householder conforms to current building regulations has a...

Страница 12: ...s which generally apply in the smoke control area In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Cle...

Страница 13: ...NOR INS REV 5 Nov 2017 Don t forget to register your stove to activate your warranty...

Отзывы: