NETcourse
Page 12
Alterations/Errors reserved 15/Wo/251D
Cassens & Plath GmbH, Am Lunedeich 131, D-27572 Bremerhaven, Germany, tel. +49 471 483 999 0, fax +49 471 483 999 10
www.cassens-plath.de
,
4.2) Installation of Junction Box
The junction box allows easy removal of the compass from the binnacle and easy
separation of detector cable.
4.3) Location of Detector and Junction Box within Compass Binnacle:
Binnacle
Compass
Detector Distance Cylinder
Cable with
Connector
Cable
Junction Box
Hood
Attention:
Make sure that detector cable does not impair free movement of
compass gimbal and that cables do not obstruct visibility of reflection
reading!