background image

 
 

CAMcourse

 

 

Page 5 

 

Alterations / Errors Reserved                                                                                                                                           16/Wo/266D 
Cassens & Plath GmbH, Am Lunedeich 131, D-27572 Bremerhaven, Germany, tel +49(0)471 483 999 0, fax +49(0)471 483 999 10 

www.cassens-plath.de

[email protected]

 

 

5. Wiring of Junction Boxes:

 

 
 

System Overview: 
 
 
 
 
 
 
 
 
 

      Camera   

 

 

 

              Monitor 

 
 
 
 
 
 
 
 
 

 

 Junction box 2 

 

      Junction box 1 

 
 
 

 

 

 

Cable, yard supply:  

 

 

 

 

4x0.14mm² min., twisted pairs, 

 

 

 

 

Schielded, max. 40m 

 
 
 

Содержание CAMcourse

Страница 1: ...o Transmitting Magnetic Compass for Overhead Compass CASSENS PLATH GmbH Manufacturers of Nautical Instruments Am Lunedeich 131 D 27572 Bremerhaven Germany tel 49 0 471 483 999 0 fax 49 0 471 483 999 10 sales cassens plath de www cassens plath de ...

Страница 2: ...ra module with mounting plate for installation above the compass with 0 5 m cable and junction box Junction box with cable 1m and plug for main indicator Built in frame Installation and operation manual Technical Data Adjustable background illuminated 7 TFT Display 18 VDC 30 VDC main emergency supply voltage Automatic switch over to emergency power supply in case of main supply failure Power consu...

Страница 3: ...rs Reserved 16 Wo 266D Cassens Plath GmbH Am Lunedeich 131 D 27572 Bremerhaven Germany tel 49 0 471 483 999 0 fax 49 0 471 483 999 10 www cassens plath de sales cassens plath de Controls Main Indicator Power on off AV1 AV2 Key Menu Key ...

Страница 4: ... on monitor By pressing menu button on monitor picture menu will be displayed By pressing menu button again the functions will be selected Adjustment of function with and Menu will be left automatically after some seconds when no key is pressed To mirror image if needed press menu button Select option by pressing key twice By pressing menu button again the functions for horizontal or vertical mirr...

Страница 5: ...nedeich 131 D 27572 Bremerhaven Germany tel 49 0 471 483 999 0 fax 49 0 471 483 999 10 www cassens plath de sales cassens plath de 5 Wiring of Junction Boxes System Overview Camera Monitor Junction box 2 Junction box 1 Cable yard supply 4x0 14mm min twisted pairs Schielded max 40m ...

Страница 6: ...ox 2 Camera 9 12V DC 10 GND 11 GND 12 Video Cable yard supply 4x0 14 min twisted pairs shielded max 40m To 2nd Monitor optional 5 12V DC 6 GND 7 GND 8 Video Power supply 13 24V DC 14 GND 15 24V DC emergency 16 GND Emergency supply 15 16 only needed if seperated from main supply 13 14 Cable yard supply 2x0 25 min twisted pair shielded max 5m 2 pieces for main and emergency supply To Junction Box 1 ...

Страница 7: ...nitor unit ref para 8 and make connections between junction box 1 and junction box 2 ref para 5 Switch on unit The picture of camera should be seen on monitor Camera is already pre adjusted by manufacturer Mirror of camera plate is faced ahead Now position the camera so that the picture of card and lubberline is displayed in centre of monitor Mark the four mounting holes of camera plate and fix ca...

Страница 8: ...ations Errors Reserved 16 Wo 266D Cassens Plath GmbH Am Lunedeich 131 D 27572 Bremerhaven Germany tel 49 0 471 483 999 0 fax 49 0 471 483 999 10 www cassens plath de sales cassens plath de Athwardship Compass Mounting Ahead ...

Страница 9: ...assens plath de 7 Adjustment of Camera 8 Installation of Monitor Unit To adjust camera loosen arrest knob 1 Rotate camera until image is centered Fix camera in that position with arrest knob After that focus camera by turning the camera lens 2 1 2 164 5mm 208mm Cut out 190mm x 140mm Monitor will be snapped in frame Plug monitor jack into socket of junction box 1 For wiring refer to paragraph 5 ...

Отзывы: