![Casio V-R100 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/casio/v-r100/v-r100_service-manual_2568734016.webp)
V-R100
– 13 –
D. AC-ADAPTOR / GEAR-BOX-ASSY
D-1. MO-SUPPORT
1. Undo two screws and dismount MO-SUPPORT.
D-2. AC-ADAPTOR
1. Undo three screws.
2.
Remove the metal fittings and AC-ADAPTOR.
Caution when replacing:
When you replace the AC-ADAPTOR with a new one,
Turn the AC cord around the ferrite core two times.
D-3. GEAR-BOX-ASSY
1. Undo two screws.
2. Dismount GEAR-BOX-ASSY.
AC-ADAPTOR
GEAR-BOX-ASSY
MO-SUPPORT
Screws (S5)
Screws (S13)
Screws (S5)
Screws (S13)
Ferrite core
Содержание V-R100
Страница 1: ...SERVICE MANUAL Ver 3 Aug 2013 V R100 EX 841 OCT 2011 ...
Страница 13: ...V R100 10 A 10 Undo three screws and disconnect three ground wires Screw S12 Screws S3 ...
Страница 43: ...V R100 40 5 3 PCB E840 1 PCB ...
Страница 44: ...V R100 41 E840 E61 PCB E840 E62 PCB E840 IOC PCB ...