P-65
TE-7000S/8000F/8500F Programming Manual
4-1-12 Programming I/O parameter
Operation
4. Select “12. I/O Parameter” and press the <YES> key.
5. Select an appropriate record, enter appropriate value (below)
and press the <YES> key.
6. Press the <ESC> key to return to the previous menu.
Worksheet for I/O parameter program
First record (Inline)
Second record (Online)
Third record (not used)
Note: Please perform the flag clear opera-
tion of the terminal after changing the
I/O parameter table.
Machine Feature
Machine Feature
6.Scheduler ¨
7.Check Print
8.Table Analysis
9.Tax Table
10.Void Table
11.System Connection
12.I/O Parameter
13.Printer Connection ´
0.00
I/O Parameter
0001-902
0000000000
0002-902 0000000000
0003-902 0000000000
0004-902 0000000000
0005-902 0000000000
0006-902 0000000000
0007-902 0000000000
0008-902 0000000000
0009-902 0000000000
0010-902 0000000000
0011-902 0000000000
0.00
Description
Choice
Program code
Online baud rate: 115200bps = 0,1
57600bps = 2,
38400bps = 3,
19200bps = 4,
9600bps = 5,
4800bps = 6,
2400bps = 7
Activation signal (trigger):
DR = 0, CI = 1
Significant
number
Significant
number
:
D
2
:
D
1
Description
Choice
Program code
Inline baud rate:
312kbps = 0
*
, 156kbps = 1
*
For INLINE 2 (CAT5) cable, select 312kbps only.
Significant
number
:
D
1
Description
Choice
Program code
Always “0”
;
D
1