8-8-2. TEST MODE
�)
While in the Timekeeping mode, hold down
B
and press
A
twice.
2)
Press
B
twice and check that the Second hand indicates the 15-second position.
3)
Press
A
to enter the Time Calibration Signal Receiving Station mode.
Each time
B
is pressed, the test signal receiving station changes as shown below.
4)
Press
A
while in the Time Calibration Signal Receiving Station mode to start receiving a signal.
* Be sure that the second hand has moved to “R” position.
�)
After approximately 15 minutes, check the indication and determine the result by referring to the
table below.
�)
Return to the Timekeeping mode by pressing
C
or by pulling out the crown and then pressing it
back in.
Reception Result
Selecting the Time Calibration Signal Receiving Station
BPC2
39 second
BPC1
42 second
JJY60
54 second
WWVB
51 second
DCF77
48 second
MSF
45 second
* “SR pull/push" in the test mode means pulling out the crown and then pressing it back in.
JJY40
JJY60
WWVB
DCF77
MSF
BPC1
BPC2
OK
3
6
9
12
15
18
21
NG
57
54
51
48
45
42
39
signal
reception
Timekeeping mode
Time calibration signal
test mode
JJY40
57 second
Reception OK
Reception NG
Reception result (Example;JJY40)
Signal reception
Crown
+
×2
×2
or SR pull/push*
Second hand
or SR pull/push*
To check Chinese signal
with TEM cell, use BPC2.
Receiving start: The second hand
indicates “R” (19-second position),
then “W” (23-second position).