3. DRAWINGS: MODULE QW-3367

3-1. LCD DIAGRAM

SAVE

CHARGE

L30

X9Y4

X10Y4
X11Y4
X16Y4
X15Y4
X14Y4
X13Y4
X12Y4

X4Y4
X3Y4
X2Y4
X1Y4
X0Y4
X5Y4
X6Y4
X7Y4

DST1

RECOVER

X8Y4

PM

SEG

COM

LC1

LC5

LC4

LC3

LC2

L26

L22

L25

L24

L23

L21

L20

L19

L18

L17

L16

L15

L14

L13

L12

L11

L10

L 9

L 8

L 7

L 6

L29

L28

L27

X9Y3

X10Y3
X11Y3
X16Y3
X15Y3
X14Y3
X13Y3
X12Y3

X4Y3
X3Y3
X2Y3
X1Y3
X0Y3
X5Y3
X6Y3
X7Y3

W8
W9
W0
W1

X8Y3

A. LIGHT

X9Y2

X10Y2
X11Y2
X16Y2
X15Y2
X14Y2
X13Y2
X12Y2

X4Y2
X3Y2
X2Y2
X1Y2
X0Y2
X5Y2
X6Y2
X7Y2

X8Y2

X9Y1

X10Y1
X11Y1
X16Y1
X15Y1
X14Y1
X13Y1
X12Y1

X4Y1
X3Y1
X2Y1
X1Y1
X0Y1
X5Y1
X6Y1
X7Y1

X8Y1

X9Y0

X10Y0
X11Y0
X16Y0
X15Y0
X14Y0
X13Y0
X12Y0

X4Y0
X3Y0
X2Y0
X1Y0
X0Y0
X5Y0
X6Y0
X7Y0

W6
W7

W2

W5

W3

W4

SIG

ALM

X8Y0

SEG

COM

L 9

L 8

L10

L11

L12

L13

L14

L15

L16

L17

L18

L19

L20

L21

L22

L23

L24

L28

L29

L30

LC4

LC2

L 7

LC5

LC3

L 6

LC1

L25

L26

L27

RECOVER

A. LIGHT

DST1

PM

CHARGE

SAVE

X0

Y0

Y4

X16

SIG

ALM

W0

W1

W2

W3

W4

W5

W6

W7

W8

W9

Содержание QW-3367

Страница 1: ...SERVICE MANUAL PARTS LIST WITHOUT PRICE QW 3367 MODULE NO R REF NO S M 914 SEP 2005 GW 1500J Ver 1 May 2006 ...

Страница 2: ...CKING TERMINALS AND COMPONENTS 12 4 EXPLODED VIEW MODULE QW 3367 13 5 PARTS LIST MODULE QW 3367 14 6 PRECAUTIONS FOR REPAIR MODULE QW 3367 6 1 AC ALL CLEAR AND REMOVING OF MODULE 15 6 2 ACCURACY CHECKING 15 6 3 SOLAR CELL PCB ASS Y CONTACT CHECKING 16 6 4 HOW TO CHECK TILT SENSOR 17 6 5 TIME CALIBRATION SIGNAL TEST MODE 17 7 TROUBLESHOOTING MODULE QW 3367 18 ...

Страница 3: ...received display Time Calibration Signal Receivable Time Calibration Signals Fukushima Japan Call Sign JJY Frequency 40kHz Fukuoka Saga Japan Call Sign JJY Frequency 60kHz Fort Collins Colorado Call Sign WWVB Frequency 60kHz World Time 29 time zones 30 cities daylight saving time on off 1 100 sec stopwatch Measuring capacity 59 59 99 Measuring modes Split time Daily alarms 1 independent daily alar...

Страница 4: ...urce you are using the case of the watch may become quite hot during charging Take care to guard against burn injury after charging To charge the battery Point the solar panel face of the watch at a light source Remember that even a partial blockage of the solar cell reduces charging efficiency Example Positioning the watch Solar Cell The illustration shows the resin band model The power supply of...

Страница 5: ...r wrist when using the auto light switch Make sure that the left 9 o clock and right 3 o clock sides of the watch are within 15 degrees of being parallel with the ground The auto light switch may not operate properly if the angle is greater Important The light may be difficult to see if you turn it on under bright sunlight If you press the B button or if an alarm operation starts while the face is...

Страница 6: ... high voltage lines Among or near buildings Receiving the Calibration Signal There are two methods you can use to receive the time calibration signal Auto receive Reception is performed automatically at midnight 1 00 2 00 3 00 and 4 00 each morning Manual receive You initiate reception using a button operation If reception is not successful for any of the normal auto receive operations shown above...

Страница 7: ...location where reception is stable while reception is in progress Unstable Stable Even under optimum reception conditions it can take about 10 seconds for reception to stabilize Use the receive indicator to check reception status and to determine the best location for signal reception Note that weather the time of day surroundings and other factors can all affect reception Receive Indicator Calibr...

Страница 8: ...MT Differential City Code City Name GMT Differential JRS JED THR DXB KBL KHI DEL DAC RGN BKK HKG SEL TYO ADL SYD NOU WLG Jerusalem Jeddah Teheran Dubai Kabul Karachi Delhi Dakar Yangon Bangkok Hong Kong Seoul Tokyo Adelaide Sydney Noumea Wellington 2 3 3 5 4 4 5 5 5 5 6 6 5 7 8 9 9 9 5 10 11 12 The contents of the above table are current as of December 2003 Time differentials in the above table ar...

Страница 9: ... When you enter the Alarm Mode the screen that was displayed when you last exited the mode appears first 2 Hold down the A A A A A button for about two seconds until the hour digits of the alarm time start to flash Displaying the alarm setting screen automatically turns on the alarm which is indicated by the alarm indicator Hour Alarm Indicator Using the Alarm and Hourly Time Signal To turn the al...

Страница 10: ... D button to toggle between 12 hour 12H and 24 hour 24H timekeeping 7 While the seconds are selected press the D D D D D button to reset them to 00 in accordance with the time signal on the radio TV etc Pressing the D button while the seconds count is in the range of 30 to 59 resets it to 00 and also adds 1 to the minutes Pressing the D button in the range of 00 to 29 resets the seconds count with...

Страница 11: ...his exits the setting screen The display also will exit the setting screen automatically if you do not perform any operation for about two or three minutes Digital Analog Synchronization After adjustment of the digital time the watch automatically adjusts its analog setting to match When adjusting the analog time the hands move clockwise Depending on how many hours different the digital and analog...

Страница 12: ... X0Y3 X5Y3 X6Y3 X7Y3 W8 W9 W0 W1 X8Y3 A LIGHT X9Y2 X10Y2 X11Y2 X16Y2 X15Y2 X14Y2 X13Y2 X12Y2 X4Y2 X3Y2 X2Y2 X1Y2 X0Y2 X5Y2 X6Y2 X7Y2 X8Y2 X9Y1 X10Y1 X11Y1 X16Y1 X15Y1 X14Y1 X13Y1 X12Y1 X4Y1 X3Y1 X2Y1 X1Y1 X0Y1 X5Y1 X6Y1 X7Y1 X8Y1 X9Y0 X10Y0 X11Y0 X16Y0 X15Y0 X14Y0 X13Y0 X12Y0 X4Y0 X3Y0 X2Y0 X1Y0 X0Y0 X5Y0 X6Y0 X7Y0 W6 W7 W2 W5 W3 W4 SIG ALM X8Y0 SEG COM L 9 L 8 L10 L11 L12 L13 L14 L15 L16 L17 L18 ...

Страница 13: ... with a soldering short pad only when one LED is mounted 18 Inclination sensor 19 No parts except Rpd are mounted within the area of the dotted line in modules without signal reception function GND VDD2 BAT VCH VDD3 VC1 VC2 C3 C2 C5 XTB Xtal L6 L30 LC1 LC5 CT LCD 2 8V 1 3b 1 5d LD1 S2 VDD1 C1 BD C8 LL1 Tr1 Tr2 XT T1 T2 T3 KI1 KI2 KI3 KI4 KI7 KI5 KI6 KI8 KI9 S1 SCR SCIN RP1 RP2 Cp PZ VDSP C4 VC3 VC...

Страница 14: ... TR1 GND N2 GND GND VDSP VC2 VC1 GND VDD1 N1 GND GND GND GND FET D XTB LL1 TR1 BD VDD2 GND TR1 LL1 VDD2 GND VCH VDD2 P14 P12 FET S KI3 VDD2 KI2 GND KI2 KI4 KI3 KI1 KI4 KI1 VHF GND VDD2 OP LEDOUT OP KI8 KI1 VOUT GND LED2 LEDOUT VOUT COIL LEDOUT LED1 SCIN SCR SCIN VSC VDD2 COIL GND VOUT GND VDD2 GND LEDOUT GND GND LD1 CE1 CE2 VSC L 9 L 8 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20 L21 L22 L23 L24 L2...

Страница 15: ...10065657 Battery storage CTL1616 15 10157977 Casing parts SOLAR CELL 10 10155782 Casing parts DIAL SPACER 5 10016598 17 76408229 PCB Ass y 8 10014042 21 72019249 13 10155784 8 10014042 9 72311777 14 10065664 8 10014042 1 76407573 4 10130977 18 72280511 11 10016591 24 10155788 8 10014042 19 10123230 19 10123230 19 10123230 ...

Страница 16: ...1 1 QW 3367AT 01TK 2 C 9 72311777 HOLDER 1381 Q456843 1 QW 3367AT 01TK 1 C 10 10155782 HOLDER 3329 RJQ518016 001V02 QW 3367AT 01TK 1 C 11 10016591 HOLDER BATTERY 2348 Q366808 1 QW 3367AT 01TK 1 C 12 10155789 HOLDER HOUR WHEEL 3329 RJQ517854 001V01 QW 3367AT 01TK 1 C 13 10155784 INTERCONNECTOR 3329 RJQ518251 001V01 QW 3367AT 01TK 1 C 14 10065664 LABEL 2368 Q468543A 1 QW 3367AT 01TK 1 C 15 10157977 ...

Страница 17: ...G Check the accuracy of the module with the quartz timer after switching the module to ACCURACY CHECKING MODE The operations are shown below A SWITCHING TO ACCURACY CHECKING MODE While pressing the D button press A and C buttons at the normal timekeeping mode Then all the segments are displayed and the LCD drive signals are changed to the static drive signal of 32 Hz so that you can check the accu...

Страница 18: ...e the watch on the desk 2 Check the display indicates as figure 2 3 Display side down and place the watch on the desk more than two seconds Or go to a dark room and place the watch more than two seconds 4 Check the display indicates as figure 3 If is not appeared on the display disassemble again the module and check the contact spring between the Solar cell and PCB 3 To exit from TEST mode Press a...

Страница 19: ...EST MODE 1 Press B C and D button at the same time to enter the test mode 2 Press A button to switch from one signal source to another J4 Fukushima Japan Call Sign JJY Frequency 40kHz J6 Fukuoka Saga Japan Call Sign JJY Frequency 60kHz U6 Fort Collins Colorado Call Sign WWVB Frequency 60kHz 3 Press D button to start signal reception Figure 4 Figure 5 Tilt the watch towards you more than 40 More th...

Страница 20: ...Home City code is selected correctly To perform MANUAL time calibration signal reception OK There is a possibility of location bad To perform AUTO time calibration signal reception Replace the PCB ass y Signal reception OK Signal reception OK Signal reception OK Replace the Case center ass y with antenna Signal reception OK OK OK OK ...

Страница 21: ...Ver 1 May 2006 Correction of pages 13 and 14 CASIO COMPUTER CO LTD Overseas Service Division 6 2 Hon machi 1 Chome Shibuya ku Tokyo 151 8543 Japan ...

Отзывы: