— 7 —

5-3.  ACCURACY CHECKING

1.  Module confirmation mode

 

1)  Press the 

 button in the Normal Timekeeping Mode to display the result of the signal receiv-

ing test.

 

2)  In the Signal Receiving Test Result Mode, press the 

 button twice while holding down the 

 

button to display the version of the Accuracy Checking Mode.

 

3)  The version is indicated with the second hand.  Press the 

 button once to display the tens 

place digit of the version; press it once more to display the units digits of the version.

 

  QW-4791: “44”

2.  Accuracy checking mode

 

1)  Press 

 button at the module confirmation mode to enter the accuracy checking mode.

 

2)  Second hand shows performing to test the rate of clock.

 

3)  Press 

 button at the Accuracy checking mode to go back to the normal timekeeping mode.

B

B

A

A

B

B

Timekeeping Mode

Press 

A

 once, and th-

en press 

B

 twice while

holding down 

A

.

TEST MODE

Accuracy Checking Mode

4 o'clock 

position

4 o'clock 

position

Indicated the last 

receiving stationis 

Signal Receiving

Test Mode

* While displaying the reception result 
   in the test mode, press the 

A

 button.

Module confirmation Mode

(units digit)

Module confirmation Mode

(tens place digit)

Indicated with the
second hand.

B

× 

2

Содержание LWQ-160DE

Страница 1: ...SERVICE MANUAL PARTS LIST WITHOUT PRICE QW 4791 MODULE NO REF NO S M 998 AUG 2007 LWQ 160DE LWQ 160LE Ver 1 May 2008...

Страница 2: ...LS AND COMPONENTS 2 3 EXPLODED VIEW MODULE QW 4791 3 4 PARTS LIST MODULE QW 4791 4 5 PRECAUTIONS FOR REPAIR MODULE QW 4791 5 1 AC ALL CLEAR AND REMOVING OF MODULE 6 5 2 MEASURING CURRENT CONSUMPTION 6...

Страница 3: ...or selection See page 7 Time calibration signal reception Auto receive Manual receive Time Calibration Signal Receivable Time Calibration Signals Fort Collins Colorado Call Sign WWVD Frequency 60kHz R...

Страница 4: ...VSC DIO2 DIO1 SCIN VCC GND VSC GND GND GND GND GND DIO14 GND GND GND GNDB P2 FET D P2 GNDB GND GND VOSC AC VDD2 DIO4 O6 P2 P1 P1 FET S P1 P2 P2 FET S VCC VSC P1 FET S VDD2 DIO1 SCIN GND GND SCR DIO2...

Страница 5: ...6410798 PCB ass y 8 10212747 9 10209123 18 10209118 1 76409228 12 10209124 11 10009244 15 10212751 13 10234346 6 10212752 3 19101199 Battery storage ESR920W 5 10209109 16 10212748 13 10234346 7 102370...

Страница 6: ...consideration of your parts usage anre repair usage for similar models MAIN PARTS Item Code No Parts Name Specification Q TY R 1 76410781 MODULE WITH MOVEMENT QW 4791AT 01TK 1 A 1 76409228 ANALOG BLO...

Страница 7: ...R 1 17 72270294 WASHER 745 Q436294A 1 1 C 18 10209118 WHEEL HOUR 4323 RJQ527219 001V01 1 C For the prices and minimum order supply quantities of the above parts refer to the Parts Price List P P L 645...

Страница 8: ...ter performing AC ALL CLEAR the mode is switched to the second hand and the indicator hand home position adjustment mode at the home position adjustment mode Metallic tweezers 5 2 MEASURING CURRENT CO...

Страница 9: ...ion QW 4791 44 2 Accuracy checking mode 1 Press button at the module con rmation mode to enter the accuracy checking mode 2 Second hand shows performing to test the rate of clock 3 Press button at the...

Страница 10: ...WVB 8sec MSF 14sec DCFF 16sec 2 Press the button to switch to the Signal Receiving Sensitivity Test Mode 3 Press the button to select the receiving station and then press the button to start receiving...

Страница 11: ...exit the setting mode The watch also will return to the Timekeeping Mode if you do not perform any operation for about two or three minutes GMT differential value 0 GMT differential value 1 GMT diffe...

Страница 12: ...me Calibration Signal Reception and Radio controlled Timekeeping Precautions Adjusting the Home Positions If the time settings are wrong even after the time calibration signal is received normally use...

Страница 13: ...check first When GMT differential GMT 1 or GMT 2 is selected In this case The first signal search operation after the GMT differential setting has been changed The second and subsequent signal searche...

Страница 14: ...CASIO COMPUTER CO LTD Overseas Service Division 6 2 Hon machi 1 Chome Shibuya ku Tokyo 151 8543 Japan Ver 1 May 2008 Correction of pages 1 and 6...

Отзывы: