— 8 —
5-4. TIME CALIBRATION SIGNAL TEST MODE
1) In the Accuracy Checking Mode, press the
button twice to switch to the signal receiving standby
state.
(The last receiving station is indicated with the second hand.)
If the last receiving station is reset with the [All Clear] function, the station to first receive the signal
is indicated.
(JJY40:4sec, JJY60:6sec, WWVB:8sec, MSF:14sec, DCFF:16sec)
2) Press the
button to switch to the Signal Receiving Sensitivity Test Mode.
3) Press the
button to select the receiving station, and then press the
button to start receiving
the signal.
The second hand will move to the READY (33-second) position.
4) The result of the signal reception will be indicated after a while.
Signal recieving department
The result of the signal reception
Success
failure
JJY40
1 o’clock
11 o’clock
JJY60
2 o’clock
10 o’clock
WWVD
3 o’clock
9 o’clock
DCF77
4 o’clock
8 o’clock
MSF
5 o’clock
7 o’clock