– 23 –
IT-9000
5-2. Initial Settings
[ NOTE ]
When the MAIN-UNIT, WAN/GPS-MODULE, or NFC-ASSY is replaced with a new one, be
sure to perform the following settings in the order indicated by “No.”.
[ NOTE ]
Be sure to perform the settings before proceeding to the function test.
No.
Item
Model Type
Remarks
1
Registration/Check of Product ID
Common
When replacing the MAIN-UNIT
USB barcode scanner
2
Upgrading WAN fi rmware
WAN
When replacing the WAN/GPS-MODULE
3
WAN settings
WAN
When replacing the WAN/GPS-MODULE
4
Upgrading NFC fi rmware
Common
When replacing the NFC-ASSY
5-2-1. Installing the Initial Setting Program and Data
How to install the initial setting program and data is the same as that for installing the test program
and test data.
For details, refer to “5-3-3. Installing the Test Program and Test Data”.
5-2-2. Setting Procedure
1. Registration/Check of Product ID
[ NOTE ]
When replacing the MAIN-UNIT with a new one, be sure to perform the following
procedure.
[ NOTE ]
To read the barcode on the back side of IT-9000, you can use a USB barcode scanner
available on the market. However, before using it, be sure that it can read the barcode
correctly.
No.
Operation
Display
Test Details
1
Start up “IDSET_PY011.exe”
under \\My Device\FlashDisk\
DIAG.
Check that an product ID write
tool has been started up.
2
Enter the barcode serial
number (product ID) written
on the back side of IT-9000.
[ NOTE ]
Enter only the rightmost 14
digits of the written number.
14 digits
Содержание IT-9000 Series
Страница 1: ...SERVICE MANUAL HANDHELD TERMINAL IT 9000 MAR 2012 Ver 8 Mar 2018...
Страница 80: ...73 IT 9000 Notes on reassembling For the camera equipped model Model C attach the tape Sheet Core...
Страница 100: ...93 IT 9000 7 1 4 I2 INNER CASE A B A B Gasket 97 Double sided tape 96 91 98 92 93 99 97 100 95 S3 94 100...