Terminal layout
1
2
3
4
5
6
1
2
3
4
5
6
Fig 2.1
•
Terminal layout and the description
Table 2.4
Terminal no.
Signal
Description
Direction
1
V BUS
Power from USB cradle OUT/IN
(see
note)
2
V CRADLE
Power supply/Charge to IT-600
-
3
D +
USB D +
IN/OUT
4
USB_ID
Switch-over between USB host and USB client
IN
5
D -
USB D -
IN/OUT
6 GND
GND
-
Note:
When the selector switch on the HA-D60IO is set to “USB Host”, this terminal is used to receive the
power ON/OFF control signal issued by the IT-600. Or, when it is set to “USB Client”, the terminal
is used to output the USB power (V BUS) to the IT-600.
2.3. HA-D32DCHG
Table 2.5
Item Specification
Remark
Charge method
Constant voltage constant current
Approx. 2 hours ( for 1 pc x HA-D20BAT)
Approx. 4 hours (for 1 pc x HA-D21LBAT)
Approx. 3.5 hours (for 2 pcs x HA-D20BAT)
Battery charge
Charge period
Approx. 7 hours (for 2 pcs x HA-D21LBAT)
At room
temperature
Required power supply
AD-S42120AE (dedicated AC adaptor)
Approx. 0.8 A (with single HA-D32DCHG)
Consumption current
Approx. 2.4 A (with three HA-D32DCHGs
connected.)
Operating temperature
Approx. 0 to 40 ºC
Operating humidity
30 to 80 %RH
No. of the chargers to be connected
3 pcs x HA-D32DCHG (maximum)
22