Terminal layout and the description 

Table 2.2 

Terminal no. 

Signal   

Description 

Direction 

V BUS 

Power from USB cradle OUT/IN 

(see 

note) 

V CRADLE 

Power supply/Charge to terminal 

D + 

USB D + 

IN/OUT 

4 NC 

 

USB_ID 

Switch-over between USB host and USB client 

IN 

D - 

USB D - 

IN/OUT 

7 GND 

GND 

Note: 
When the selector switch on the HA-D60IO is set to “USB Host”, this terminal is used to output the 
power ON/OFF control signal issued by the IT-600 to the cradle. Or, when it is set to “USB Client”, 
the terminal is used to input the USB power (V BUS) from the cradle to the IT-600. 
 

 

20

Содержание IT-600M30

Страница 1: ...IT 600 Series Hardware Manual Version 1 00 CASIO Computer Co Ltd Copyright 2005 All rights reserved November 2005...

Страница 2: ...21 2 3 HA D32DCHG 22 2 4 HA D30CHG 23 2 5 HA D20BAT HA D21LBAT 23 2 6 HA D50BN 24 Chapter 3 Product Identification And Reference Numbers 25 Chapter 4 Quality References 26 4 1 Environmental Performan...

Страница 3: ...the express written permission of CASIO Computer Co Ltd in Tokyo Japan Information in this document is subject to change without advance notice CASIO Computer Co Ltd makes no representations or warra...

Страница 4: ...Editorial Record Manual Version no Date edited Page Content 0 90 November 2005 Tentative version 1 00 November Original version 4...

Страница 5: ...tions via either Bluetooth or WLAN IEEE802 11b g Rugged casing to allow use in extreme environments Original CASIO digital technology enables capturing of images in all light conditions Microsoft Wind...

Страница 6: ...environment Resistance to fall impact 1 2 m in height Dust Water splash proof IP54 compliant with IEC60529 International Standard Capable of scanning industrial standard bar code symbologies Readable...

Страница 7: ...30CHG Cradle type Charger Battery charger HA D32DCHG Dual Battery Charger Laser Redirection Attachment HA D50BN Change the laser emission to downward at 60 degree CF Card Extension Unit HA D94CFU For...

Страница 8: ...1 23 4 16 22 20 23 25 26 24 21 14 22 5 6 7 8 9 12 13 10 11 19 15 18 17 10 1 23 4 16 22 20 23 25 26 24 21 14 22 5 6 7 8 9 12 13 10 11 19 15 18 Fig 1 1 See Table 1 4 for the descriptions for each refer...

Страница 9: ...left of the input key 11 Numeric Keys Used to enter numbers or letters 12 Microphone Used to input a sound including voice 13 Speaker Alarms and voice messages are output here Voice messages are not...

Страница 10: ...HA D60IO The following external views show the HA D60IO USB Cradle Refer to Table 1 5 for each referenced part on the HA D60IO Views Front Top Rear 8 7 5 6 4 3 2 1 Front Top Rear 8 7 5 6 4 3 2 1 Fig 1...

Страница 11: ...USB host port and USB client port 4 AC Adaptor Jack Connect the dedicated AC adaptor here 5 Terminal Detect Switch This switch detects when the Handheld Terminal is mounted correctly on the Cradle 6 P...

Страница 12: ...No Name Description These lamps indicate the charge status of each battery pack Off Not charging Red Charging Red Flashing Battery pack problem 1 Charge indicator lamps Green Charging complete 2 AC ad...

Страница 13: ...tor here 2 Terminal Detect Switch This switch detects when the Handheld Terminal is mounted correctly on the charger 3 Power Contacts Power is supplied to the handheld Terminal via these contacts This...

Страница 14: ...1 5 5 HA D50BN Laser Redirection Attachment View Fig 1 5 14...

Страница 15: ...1 5 6 Device Configuration Diagram Fig 1 6 15...

Страница 16: ...mm When the distance is at 40 mm Max 250 mm When the distance is at 300 mm Readable width Max 60 mm contact scanning When HA D50BN is attached Daylight for scanning 50 000 Lux or less Readable 1D bar...

Страница 17: ...o 2 4835 GHz Baud rate IEEE802 11b 11 Mbps maximum IEEE802 11g 54 Mbps maximum Comm range IEEE802 11b 50 m indoor to 150 m outdoor IEEE802 11g 50 m indoor to 150 m outdoor Vary depending on the enviro...

Страница 18: ...ce 1 4 5 type CCD color Aperture F3 5 F7 0 2 steps switchover Focal distance f 3 29 mm fixed Image capture range 30 cm to LED light Brightness 3300 mcd Power Operation Lithium ion battery pack HA D20B...

Страница 19: ...prox 10 minutes Clock Approx 72 hours Lithium battery pack is fully charged At room temperature Battery pack charge period Approximately 4 hours for HA D20BAT Approximately 7 hours for HA D21LBAT The...

Страница 20: ...USB D IN OUT 4 NC 5 USB_ID Switch over between USB host and USB client IN 6 D USB D IN OUT 7 GND GND Note When the selector switch on the HA D60IO is set to USB Host this terminal is used to output t...

Страница 21: ...J RC 5320Atype 4 Center Power fromAC adaptor AC adaptor AD S42120AE Standard USB Ver 1 1 compatible Baud rate 12 Mbps maximum 1 5 Mbps minimum USB host Power to external device 5V 5 maximum 500 mA Sta...

Страница 22: ...n it is set to USB Client the terminal is used to output the USB power V BUS to the IT 600 2 3 HA D32DCHG Table 2 5 Item Specification Remark Charge method Constant voltage constant current Approx 2 h...

Страница 23: ...rent limitation control Approx 4 hours for HA D20BAT Power supply Charge Charge period Approx 7 hours for HA D21LBAT 2 5 HA D20BAT HA D21LBAT HA D20BAT Battery Pack Table 2 7 Item Specification Remark...

Страница 24: ...2 6 HA D50BN Table 2 9 Item Specification Remark Angle of laser beam emission 60 downward Dimensions Approx 91 2 W x 63 15 L x 45 9 H mm Weight Approx 60g 24...

Страница 25: ...erences of each terminal The numbers from 10 to 15 represent a manufacturing reference which is reserved by the manufacturer See the figure below for each meaning 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 P...

Страница 26: ...operation 20 C to 60 C Humidity Operation 10 to 80 RH Non operation 5 to 90 RH No condensation Storage Temperature 20 C to 60 C Humidity 5 to 90 RH No condensation Dust and water splash proof IP54 lev...

Страница 27: ...ature 20 C to 60 C Humidity 10 to 90 RH No condensation Dust and water splash proof Not applicable 4 1 4 HA D30CHG Table 4 4 Item Specification Condition Temperature Operation 0 C to 40 C Non operatio...

Страница 28: ...ature Operation 10 C to 50 C Non operation 20 C to 60 C Humidity Operation 10 to 80 RH Non operation 5 to 90 RH No condensation Storage in carton box Temperature 20 C to 60 C Humidity 90 RH or less No...

Страница 29: ...strength Malfunction 4 KV Destruction 12 KV 150 pF 330ohm 4 2 2 HA D60IO Table 4 7 Item Specification Remark Input voltage DC12V 5 Anti static strength In contact 6 KV In air 8 KV 150 pF 330 ohm Powe...

Страница 30: ...ir 8 KV 150 pF 330 ohm Line noise strength Malfunction 1 000 V Pulse frequency 5KHz Burst cycle 300 millisec Number of pulses 75 Burst interval 15 millisec 4 2 4 HA D30CHG Table 4 9 Item Specification...

Страница 31: ...Z directions Reciprocally for 30 minutes 4 3 2 HA D60IO Table 4 11 Item Specification Condition Resistance to vibration 1 5 G or less 10 to 55 Hz In X Y and Z directions Reciprocally for 30 minutes W...

Страница 32: ...less 1 cycle on each of the 6 sides 6 faces 1 corner and 3 edges On to concrete floor 4 3 4 HA D30CHG Table 4 13 Item Specification Condition Resistance to vibration 1 5 G or less 10 to 55 Hz In X Y...

Страница 33: ...With HA D50BN being attached on IT 600 Resistance to impact In bare condition 120 cm 1 cycle on each of the 6 sides 6 faces 1 corner and 3 edges On to concrete floor With HA D50BN being attached on I...

Страница 34: ...nge of temperature between 25 C and 30 C At 80 charge level 20 000 times Memory backup for a period of 10 minutes Discharge charge cycle longevity of memory backup battery 40 times Memory backup until...

Страница 35: ...cification Condition MTBF for electronic parts 50 000 hours Mounting a battery pack and removing 5 000 times Connecting to the joint connector and removing from 250 times Installing AC adaptor to and...

Страница 36: ...00M30CR See note See note Yes Yes Yes Yes Note IT 600M30R and IT 600M30CR are compliant with the respective criteria set on the EN55022 and EN55024 standards The WLAN type approval requires both the m...