Casio GW-1200BCJ Скачать руководство пользователя страница 12

— 10 —

3. DRAWINGS: MODULE QW-3334

3-1. LCD DIAGRAM

L 7
L 8
L 9

L10
L11
L12
L13
L14
L15
L16
L17
L18
L19
L20
L21
L22

LC1

LC2

LC3

LC4

LC5

SEG

COM

WT2

MID

TIME

TR

WT

AL

DST

HIGH

PM

X8Y3

X8Y1

X8Y2

X1Y2

X8Y0

X2Y3

X1Y1

X1Y0

X8Y4

X1Y4

x2y4

X1Y3

X2Y0

X2Y2

X2Y1

ANT2

SAVE

RECOVER

AUTOLIGHT

SIG

ALM

W0

ANT0

LCHARGE

SEG

COM

WT2

DST

PM

MID

HIGH

X0

LC5

LC2

L31

L32

L33

L29

L37

L36

LC5

L34

L35

LC4

LC3

L30

L28

LC5

LC4

L24

L25

L26

L10

L11

L12

L13

L14

L15

L16

L21

LC3

LC2

LC1

L20

L19

L30

L17

L18

L23

L22

L

 7

L 8

L 9

LC4

L27

LC1

H-SET

ST

X3Y3

X3Y1

X3Y2

X3Y0

X3Y4

X4Y3

X4Y1

X4Y2

X4Y0

X4Y4

X5Y3

X5Y1

X5Y2

X5Y0

X5Y4

X6Y3

X6Y1

X6Y2

X6Y0

X6Y4

X7Y3

X7Y1

X7Y2

X7Y0

X7Y4

X0Y4

X0Y0

X0Y3

X0Y1

X0Y2

X9Y4

X9Y0

X9Y3

X9Y1

X9Y2

X10Y4

X10Y0

X10Y3

X10Y1

X10Y2

X11Y4

X11Y0

X11Y3

X11Y1

X11Y2

L23

L25
L26
L27

L32
L33

L24

L31

L36
L37

L35

L34

COM

SEG

L30

L28
L29

LCHARGE

SAVE

w1

ANT0

ALM

a0

d0

e0

f0

W0

c0

W3

b0

g0

W2

ANT2

RECOVER

X16Y4

X16Y0

X16Y3

X16Y1

X16Y2

W4

AUTOLIGHT

ANT1

b1

c1

d1

a1

f1

g1

e1

W9

W7

W6

W5

SIG

W8

X12Y4

X12Y0

X12Y3

X12Y1

X12Y2

X13Y4

X13Y0

X13Y3

X13Y1

X13Y2

X14Y4

X14Y0

X14Y3

X14Y1

X14Y2

X15Y4

X15Y0

X15Y3

X15Y1

X15Y2

TR

ST

WT

W1

H-SET

TIME

AL

ANT1

W2

W3

W4

W5

W6

W7

W8

W9

X16

Y0

Y4

b1

e0

f0

d0

a1

c0

g0

b0

a0

g1

c1

d1

e1

f1

LC1

LC2

LC3

LC4

LC5

Содержание GW-1200BCJ

Страница 1: ...SERVICE MANUAL PARTS LIST WITHOUT PRICE QW 3334 MODULE NO R REF NO S M 872 NOV 2004 GW 1200BCJ...

Страница 2: ...DIAGRAM 11 3 3 CHECKING TERMINALS AND COMPONENTS 12 4 EXPLODED VIEW MODULE QW 3334 13 5 PARTS LIST MODULE QW 3334 14 6 PRECAUTIONS FOR REPAIR MODULE QW 3334 6 1 AC ALL CLEAR AND REMOVING OF MODULE 15...

Страница 3: ...easuring capacity 59 59 99 Measuring modes Elapsed time Countdown timer Input range 1 minute to 60 minutes Unit 1 10 second repeat timer 1second auto repeat timer Others Auto repeat 5 independent dail...

Страница 4: ...d Date Leaving the watch in a drawer or anywhere else it is dark can cause the power saving mode to trigger in order to conserve battery power Power Saving Each press of the C C C C C button sounds a...

Страница 5: ...disabled whenever battery power is at Level 3 or lower The display may illuminate unintentionally when you wear the watch on the inside of your wrist when you shake your arm or when you raise your ar...

Страница 6: ...ontrolled watch Your radio controlled watch is designed to receive a time calibration signal that contains standard time data and adjust its current time setting accordingly Signal is received using b...

Страница 7: ...thods you can use to receive the time calibration signal Auto receive Reception is performed automatically at midnight 1 00 2 00 3 00 and 4 00 each morning Manual receive You initiate reception using...

Страница 8: ...s after the watch successfully receives the calibration signal and adjusts the current time setting A single receive operation was not successful The watch is not in the Timekeeping Mode or World Time...

Страница 9: ...timing to restart from the start time when the end of the countdown is reached The countdown repeats up to 10 times or until you stop it manually Configuring Timer Settings 1 In the Timer Mode hold d...

Страница 10: ...dial but timing of the next split continues internally Changing to another mode while a split time is displayed cancels the split time operation Pressing the B button while timing is stopped resets th...

Страница 11: ...ically if you do not perform any operation for about two or three minutes Digital Analog Synchronization The watch automatically adjusts its analog setting to match the current digital time setting Wh...

Страница 12: ...1 H SET ST X3Y3 X3Y1 X3Y2 X3Y0 X3Y4 X4Y3 X4Y1 X4Y2 X4Y0 X4Y4 X5Y3 X5Y1 X5Y2 X5Y0 X5Y4 X6Y3 X6Y1 X6Y2 X6Y0 X6Y4 X7Y3 X7Y1 X7Y2 X7Y0 X7Y4 X0Y4 X0Y0 X0Y3 X0Y1 X0Y2 X9Y4 X9Y0 X9Y3 X9Y1 X9Y2 X10Y4 X10Y0 X1...

Страница 13: ...DD8 CE27 6CE1 LED2 Di LL2 LED1 Rld1 Rld2 Cld1 Cld2 Rpd BAT1 10 7 4 6 5 6 4 4 3 3 3 3 3 3 9 9 8 11 14 14 14 14 15 14 13 14 12 1 1 1 1 1 3 3 2 2 LSI TOTAL 106PINS BONDING 80PINS 1 No bonding 2 GND KI6 O...

Страница 14: ...VDD2 R1 GND VDD2 GND L2 VDD3 R3 R1 KI6 VOUT R1 VOUT R2 N2 GND R2 SCIN N1 GND VSC GND GND R1 R2 LEDOUT GND VHF GND GND VDD1 LEDOUT KI7 GND GND VSC SCIN SCR GND SCIN KI4 GND KI3 KI1 L1 GND KI5 L2 KI8 G...

Страница 15: ...1014 4880 1 7640 7410 4 7235 0891 24 1007 4152 25 7227 0273 26 1012 3230 29 7230 0665 26 1012 3230 9 7231 1777 15 1014 4877 22 1013 7168 Casing parts SOLAR CELL Casing parts DIAL SUPPORTER Casing part...

Страница 16: ...LDER HOUR WHEEL RJQ516824 001V01 QW 3334YC 02TK 1 C 12 1014 4874 INTERCONECTER 3334 1 RJQ516818 001V01 QW 3334YC 02TK 1 C 13 1014 4876 INTERCONECTER 3334 3 RJQ516820 001V01 QW 3334YC 02TK 1 C 14 1016...

Страница 17: ...the module with the quartz timer after switching the module to ACCURACY CHECKING MODE The operations are shown below A SWITCHING TO ACCURACY CHECKING MODE While pressing the D button press A and C bu...

Страница 18: ...dark room and place the watch more than two seconds 4 Check the display indicates as figure 3 If 88 is not appeared on the display disassemble again the module and check the contact spring between th...

Страница 19: ...igital display is completely blank Yes No Yes No Yes No Yes No START Check whether the Home City code is selected correctly To perform MANUAL time calibration signal reception OK There is a possibilit...

Страница 20: ...CASIO TECHNO CO LTD Overseas Service Division 6 2 Hon machi 1 Chome Shibuya ku Tokyo 151 8543 Japan...

Отзывы: