– 6 –
QW-3403
5. REPLACEMENT OF BATTERY: MODULE QW-3403
5-1. AC (ALL CLEAR)
Be sure to perform AC (All Clear) after a battery is replaced.
Unless AC is performed, the memory(s) and/or counter(s) may not be initialized and cause malfunc
-
tions.
Touch the AC contact and the main plate with metallic tweezers.
The contact should be made for about two seconds.
5-2. SETTINGS AFTER AC
Function
Settings
After AC Mode
Timekeeping Mode
Timekeeping Mode
Date: Friday, January 1, 2010 12:00:00 AM
Time Difference: UTC+9
DST: OFF
Light afterglow: 1.5 sec.
VIB/Flash & BEEP: VIB
Button Operation Tone: BEEP (ON)
Auto Light: OFF
World Time
WT City Code: (UTC)
Date: December 31, 2009 3:00:00 PM
DST: All Cities OFF
Alarm
Setting: AL1
Time: 12:00 AM (SNZ, AL1-4)
Alarm: OFF (SNZ, AL1-4)
Hourly Time Signal: OFF
Stopwatch
Setting: “Reset” (0H 00’00’’00)
Timer
Setting: “Reset” (0H 10’00’0)
Start Time: 0 hours 10 minutes 00 second