E-39
DIP Switch Settings
The settings of the DIP switches located on the bottom of the Optical Communication Unit
can be adjusted to achieve the desired hardware configuration.
1 2 3 4 5 6 7 8 9 10
Flow Control
9
10
Off
OFF
OFF
X ON/X OFF
ON
OFF
RS/CS
OFF
ON
Use Special Software ON
ON
Optical Communication Unit - Host
Computer Communication speed
6
7
8
2,400bps
OFF
OFF
OFF
4,800bps
ON
OFF
OFF
9,600bps
OFF
ON
OFF
19,200bps
ON
ON
OFF
38,400bps
OFF
OFF
ON
57,600bps
ON
OFF
ON
115,200bps
OFF
ON
ON
* Communication speed can be set by
Data Collector overrides this setting.
Connection Type
3
4
5
Host Computer
OFF
OFF
ON (No linking)
Connection
OFF (Linking)
Intermediate Unit
ON
OFF
OFF
in Linked Chain
Terminator Unit
ON
OFF
ON
in Linked Chain
Important!
• Other settings not shown here are used for special-purpose modes,
and should not be used.
Data Collector - Optical Communication
Unit Communication Speed
1
2
38,400bps
OFF
OFF
115,200bps
ON
OFF
230,400bps
OFF
ON