background image

Operation Guide DQR-100

4

BATTERY REPLACEMENT

Low Battery Warning

 indicator appears on the display to let you know when battery power is low. Replace the batteries as soon

as possible.
Note that the 

 indicator appears on both the main unit and sub-unit when sub-unit battery power goes low.

To replace main unit batteries

Replace batteries whenever the display of the clock becomes dim and difficult to read.
1. Open the battery compartment cover as shown in the illustration.
2. Remove all of the old batteries.
3. Load a full set of new batteries. Make sure that their positive (+) and negative (–) ends face in the correct

directions. If you load batteries incorrectly, they can burst and damage the clock.

4. Replace the battery compartment cover.
5. Press the RESET button (

6

). Be sure to press the RESET button (

6

) after replacing batteries.

To replace sub-unit batteries

1. Rotate the battery compartment cover from LOCK to OPEN.
2. Remove both old batteries.
3. Load new batteries. Make sure that their positive (+) and negative (–) ends face in the correct directions. If you

load batteries incorrectly, they can burst and damage the clock.

4. Replace the battery compartment cover.
5. Press the RESET button (

B

). Be sure to press the RESET button (

B

) after replacing batteries.

6. Press the RE-SYNC button (

0

).

Battery precautions

Keep batteries out of the reach of small children. If a battery is accidentally swallowed, contact your physician
immediately.

Be sure to load the batteries with their positive (+) and negative (–) ends facing correctly.

Never mix old and new batteries, or batteries of different brands.

Never charge the batteries that come with the clock.

Should batteries ever leak while in the clock, wipe out the fluid with a cloth, taking care not to let any get onto
your skin.

Replace the batteries at least once a year, even if the current batteries are working properly.

The batteries that come with the clock lose some of their power during transport and storage.

THERMOMETER FUNCTIONS

Both the main unit and the sub-unit are equipped with their own temperature sensors. Temperature data measured
by the sub-unit is sent by wireless transfer to the main unit. This makes it possible to view both the indoor and
outdoor temperature on the main unit display.

Temperature Measurements

Both the main unit and the sub-unit take temperature measurements every 16 seconds.

The temperature display shows “LO” for temperatures below –50

°

C (–58

°

F) and “HI” for temperatures above

70

°

C (158

°

F).

Though temperature readings are displayed up to 0

°

C (32

°

F) and greater than 41

°

C (105

°

F), note that such

readings are actually outside the guaranteed temperature range of this clock.

Switching between Celsius and Fahrenheit

Push the 

°

C/ 

°

F button  (

9

) to select either Celsius (

°

C) or Fahrenheit (

°

F).

 Celsius (

°

C)

Fahrenheit (

°

F)

°

C/ 

°

F button (

9

)

°

C

°

F

°

F

°

C

Main unit
(INDOOR)

Sub-unit 
(OUTDOOR)

High Temperature and Low Temperature Memory

The following data is stored in memory automatically.
Main unit high temperature and low temperature
Sub-unit high temperature and low temperature

To clear the high temperature and low temperature data memory, press the CLEAR button (

8

).

New data starts to be stored after memory is cleared.

CLEAR button (

8

)

Current temperature

MAX/MIN TEMP. button (

7

)

Main unit high temperature and low temperature

Sub-unit high temperature and low temperature

Содержание DQR-100

Страница 1: ...ations subject to radio frequency interference the product may malfunction and require you to reset the product Main unit Sub unit SNZ ON OFF SET U P W AV E R E S Y N C C F D O W N RESET TEMP MAX MIN CLEAR ALM SNZ ON OFF ALM SET U P W A V E R E S Y N C C F D O W N RESET TEMP MAX MIN CLEAR 1 7 4 3 9 8 0 6 2 2 1 5 Alarm on indicator PM indicator Wave OK indicator Antenna Icon Current Temperature OUT...

Страница 2: ...n it is receiving the calibration signal When receiving indoors move to a location as near as possible to a window Proper signal reception can be difficult or even impossible under the conditions listed below 1200 km 500 km Mainflingen Inside among buildings or near neon signs Inside a vehicle Near refrigerators or other household appliances near office equipment mobile phones or wireless LAN devi...

Страница 3: ...levels as it sounds Stopping the Alarm When alarm is sounding press the SNOOZE LIGHT button 1 to stop it When the snooze feature is turned on the alarm will sound again in about five minutes To turn off the snooze feature slide the Alarm Mode selector 5 to OFF USING THE LIGHT Pressing the SNOOZE LIGHT button 1 turns on the light and illuminates the display for easy reading in the dark Important Ov...

Страница 4: ...ries of different brands Never charge the batteries that come with the clock Should batteries ever leak while in the clock wipe out the fluid with a cloth taking care not to let any get onto your skin Replace the batteries at least once a year even if the current batteries are working properly The batteries that come with the clock lose some of their power during transport and storage THERMOMETER ...

Страница 5: ... operation is not successful for some reason the display of the main unit shows dashes in place of the sub unit temperature value If you experience problems with data transfer press the RE SYNC button 0 to synchronize the two units If this does not eliminate the problem try changing the positions or orientations of the main unit and sub unit Switching between Celsius and Fahrenheit Push the C F bu...

Отзывы: