Interpreting Altitude Graph Contents

50m*

6 readings ago

Current reading

* 1 square (

v

) is 10 m.

Calibrating Altitude

Readings (Offset)

To minimize the difference between locally
indicated and measured values, you should
update the reference altitude value (offset)
before setting off and during treks or any other
activities where you take altitude readings.
Also, you can ensure accurate measurements
by checking a map local altitude indications or
some other source for your current location’s
altitude, and regularly calibrating watch
readings with the latest information while
mountain climbing.

Note

You can find out the altitude at your
current location from signs, maps, on
the Internet, etc.

Differences between actual altitude
and watch readings can be caused by
the factors below.

ー 

Changes in barometric pressure

ー 

Changes in temperature caused by
variations in barometric pressure
and by elevation

Though altitude readings can be taken
without calibration, doing so may
produce readings that are very
different from indications by altitude
markers, etc.

1.

Enter the Altimeter Mode.

l

Navigating Between Modes

2.

Pull out the crown.

This displays the current altitude and
enters the Altitude Offset Mode.

Crown

3.

Rotate the crown to calibrate the
displayed value to that of a local altitude
(elevation) marker.

Setting range: -3,000 to 10,000 meters
Setting unit: 1 meter

To return the altitude setting to its initial
factory default, press (A) and (C) at the
same time.

4.

Push the crown back in to complete the
setting operation.

Note

If you do not perform any operation for
about two minutes after pulling out the
crown, crown operations will
automatically become disabled. If that
happens, push the crown back in and
then pull it out again.

Checking the Altitude

Differential from a Reference

Point

After you set a reference altitude, the second
hand of the watch will indicate the difference
between your current altitude and the
reference altitude. This makes it easy to
measure the altitude difference between two
points while climbing or trekking.

Setting the Altitude Differential
Measurement Range

1.

Enter the Altimeter Mode.

l

Navigating Between Modes

2.

Pull out the crown.

This displays the altitude for your current
location.

Crown

3.

Press (B) twice.

This displays the altitude differential
measurement range.

4.

Rotate the crown to select either [100m] or
[1000m].

[100m]: ±100 meters (±328 feet) in 5-
meter (16-foot) units
[1000m]: ±1000 meters (±3280 feet) in
50-meter (164-foot) units

5.

Push the crown back in to complete the
setting operation.

Watch Operation Guide 5678

21

Содержание 5678

Страница 1: ...cking the Current Altitude Calibrating Altitude Readings Offset Checking the Altitude Differential from a Reference Point Setting the Auto Measurement Interval Recording Altitude Readings Specifying t...

Страница 2: ...inspect your watch for proper water resistance whenever you have its battery replaced Battery replacement requires the use of special tools Always request battery replacement from your original retail...

Страница 3: ...ther with other items for long periods while it is wet can cause color on resin components to transfer to the other items or the color of the other items to transfer to the resin components of your wa...

Страница 4: ...t or soap For a resin band wash with water and then wipe dry with a soft cloth Note that sometimes a smudge like pattern may appear on the surface of a resin band This will not have any effect on your...

Страница 5: ...erence only Whenever using the Digital Compass of this watch for serious trekking mountain climbing or other activities be sure to always take along another compass to confirm readings If the readings...

Страница 6: ...indicates altitude barometric pressure differential K Displayed when an alarm is turned on L Appears when the hourly time signal is on M Displayed when the indicated time is summer time N Displayed w...

Страница 7: ...e at 12 o clock Barometer Mode Use this mode to take barometric pressure readings at your current location l Barometric Pressure Measurement Remeasure Display screen navigation A Barometric pressure d...

Страница 8: ...rd Fast Reverse Second click First click Normal timekeeping Crown After pullingoutthe crowntothefirstorsecond click rotating it quickly in succession in either direction will start a fast forward or f...

Страница 9: ...igh temperatures This is temporary and the display will return to normal at lower temperatures Checking the Charge Level A display indicator shows the watch s charge level when you enter the Timekeepi...

Страница 10: ...exit power saving Press any button Move the watch to a bright location Trigger auto light by angling the watch towards your face Note The watch will not enter power saving in the cases below While in...

Страница 11: ...auses CITY to flash on the display and the second hand to move to the current Home City Second hand Home City Crown 3 Press B four times LIGHT appears on the display with 1 or 3 flashing 4 Rotate the...

Страница 12: ...eption range of the U K and German time signals is approximately 1 500 km from each transmission station Note Even if you are within the normal reception range of a time calibration signal reception m...

Страница 13: ...s are affected by weather the time of day the surrounding environment etc Checking the Last Time Adjustment Result 1 Enter the Receive Mode l Navigating Between Modes This displays the date and time o...

Страница 14: ...me ON The watch always indicates summer time 6 Push the crown back in to complete the setting operation Note If you do not perform any operation for about two minutes after pulling out the crown crown...

Страница 15: ...H to flash on the display 4 Rotate the crown to select 12H 12 hour timekeeping or 24H 24 hour timekeeping Crown 5 Push the crown back in to complete the setting operation Note If you do not perform an...

Страница 16: ...it out again While UTC is selected as the city you will not be able to change or check the summer time setting Specifying UTC Coordinated Universal Time as Your World Time City To set UTC Coordinated...

Страница 17: ...while the hourly time signal is enabled Turning Off an Alarm or the Hourly Time Signal To stop an alarm or the hourly time signal from sounding perform the steps below to turn it off To have an alarm...

Страница 18: ...operation is in progress If an alarm or other beeper sounds or if you turn on illumination by pressing L while a compass operation is in progress the compass operation will be suspended momentarily T...

Страница 19: ...Example For an angle of 7 4 set 7 Example For an angle of 7 40 7 degrees 40 minutes set 8 Note Magnetic declination angles east or west and angle degree values for specific locations can be found on...

Страница 20: ...ude elevation indications l Calibrating Altitude Readings Offset Check the information at the link below to find out about how to minimize differences between readings produced by the watch and values...

Страница 21: ...the Altitude Offset Mode Crown 3 Rotate the crown to calibrate the displayed value to that of a local altitude elevation marker Setting range 3 000 to 10 000 meters Setting unit 1 meter To return the...

Страница 22: ...le Altitude differential of 30 m 98 feet 300 m 984 feet 100 50 0 50 100 Altitude differential indicator Unit m Range 100 m 1000 m 328 feet 3280 feet Note You can toggle between the two second hand fun...

Страница 23: ...ch is in the Altitude Mode One record each is maintained in memory for each of these items A B C D F E End point Start point High Altitude MAX E Low Altitude MIN F Cumulative Ascent ASC A C Cumulative...

Страница 24: ...how to ensure correct readings l Calibrating Barometric Pressure Readings Offset l Barometric Pressure Reading Precautions Checking the Current Barometric Pressure 1 Enter the Barometer Mode l Naviga...

Страница 25: ...9 inHg 10 5 0 5 10 Pressure Differential Indicator Range 10 hPa 1 hPa units Unit hPa Note You can toggle between the two second hand functions by pressing D l Checking the Current Barometric Pressure...

Страница 26: ...e value you use for calibration produces correct pressure readings 1 Enter the Barometer Mode l Navigating Between Modes 2 Pull out the crown This displays the current barometric pressure and enters t...

Страница 27: ...ng the Current Temperature 1 Enter the Temperature Mode l Navigating Between Modes Entering the Temperature Mode will start temperature measurement and display the result After you enter the Temperatu...

Страница 28: ...become disabled If that happens push the crown back in and then pull it out again Specifying the Temperature Measurement Unit You can select either Celsius C or Fahrenheit F as the temperature display...

Страница 29: ...eeds 99 999 m 327 995 feet it will revert to 0 and continue from there Pressing D returns to the top screen record number DSC ASC MAX or MIN of the data that you are viewing If you do not perform any...

Страница 30: ...asure split times Measuring Elapsed Time 1 Enter the Stopwatch Mode l Navigating Between Modes 2 Use the operations below to measure elapsed time A A A A Stop Resume Stop Start Hours minutes seconds 1...

Страница 31: ...eper will sound for 10 seconds to let you know when the end of a countdown is reached You can reset a paused countdown to its start time by pressing C 3 Press any button to stop the tone Hand Alignmen...

Страница 32: ...he tone that sounds when you press a button 1 Enter the Timekeeping Mode l Navigating Between Modes 2 Pull out the crown This causes CITY to flash on the display and the second hand to move to the cur...

Страница 33: ...in the above table is current as of January 2021 Time zones may change and UTC differentials may become different from those shown in the table above Specifications Accuracy 15 seconds per month aver...

Страница 34: ...and LED backlight for LCD with Full Auto Light Super Illuminator afterglow afterglow duration setting 1 5 seconds 3 seconds alarm testing automatic hand position correction power saving charge level b...

Страница 35: ...at you regularly calibrate its readings in accordance with local altitude elevation indications l Calibrating Altitude Readings Offset Q2 Following a relative altitude reading the watch s second hand...

Страница 36: ...onfigure the alarm settings l Configuring Alarm Settings Q2 The hourly time signal does not sound Is the watch s battery charged Keep the watch exposed to light until it recharges sufficiently l Charg...

Страница 37: ...rown operations l Using the Crown Charging Q1 The watch does not work even though it is exposed to light The watch stops operating whenever the battery goes dead Keep the watch exposed to light until...

Отзывы: