Battery Power Indicator and Recover Indicator

The battery power indicator on the display shows you the current status of the
rechargeable battery’s power.

Battery power
indicator

Level

1

2

3

4

5

Battery Power Indicator

Function Status

All functions enabled.

All functions enabled.

Illumination, beeper tone,
receive operation, and sensors
disabled.

All functions disabled.

All functions disabled.
All settings revert to factory defaults.

(Charge Soon Alert)

l l l l

ll

ll

ll

ll

ll

ll

l l

l l l l l

l l

l

l

l

ll

ll

ll

l

l

l

l l

l l

(Charge Soon Alert)

l l ll

lll

ll

ll

ll

ll

ll

l l l l l l

The flashing 

LOW

LOW

LOW

LOW

LOW

 indicator at Level 3 and the 

CHG

 indicator flashing at

Level 4 tell you that battery power is very low, and that exposure to bright
light for charging is required as soon as possible.

At Level 5, all functions are disabled and settings return to their initial
factory defaults. Once the battery reaches Level 2 (

M

) after falling to Level

4, reconfigure the current time, date, and other settings.

Display indicators reappear as soon as the battery is charged from Level 5
to Level 2.

Leaving the watch in direct sunlight or some other very strong light source
can cause the battery power indicator to show a reading temporarily that is
higher than the actual battery level. The correct battery power indicator
should appear after a few minutes.

If you use illumination or the alarm a number of
times during a short period, 

RECOV

 appears

on the display and the illumination, alarm,
hourly time signal, and sensor operations
become disabled until battery power recovers.
After some time, battery power will recover and

RECOV

 will disappear, indicating that the

above functions are enabled again.

Recover indicator

Even if battery power is at Level 1 or Level 2, the Digital Compass Mode,
Barometer/Thermometer Mode, or Depth Gauge Mode sensor may be
disabled if there is not enough voltage available to power it sufficiently. This
is indicated by 

RECOV

 on the display.

If battery power goes low while a measurement operation is in progress,
the value produced by the last successful measurement operation remains
on the display. Attempting a measurement operation while battery power is
too low will cause the display to go blank.
Sensor operation should resume when battery voltage returns to normal levels.

If 

RECOV

 starts to flash on the display when you enter the Depth Gauge Mode

(before starting measurement), the log data date will not be recorded if you
start measurement after 

RECOV

 disappears from the display. In this case, exit

and re-enter the Depth Gauge Mode, and then start the measurement again.

If 

RECOV

 starts to flash while a Depth Gauge Mode depth measurement

operation is in progress, the measurement operation will continue. Though
the elapsed measurement time will be recorded in log memory, maximum
depth and water temperature values are not. In this case, 

xx

.

x

 is displayed

in place of the maximum depth and water temperature. After you surface
from your dive, hold down 

D

 for about three seconds to exit the Depth

Gauge Mode to clear 

RECOV

.

If 

RECOV

 appears frequently, it probably means that remaining battery

power is low. Leave the watch in bright light to allow it to charge.

Charging Precautions

Certain charging conditions can cause the watch to become very hot. Avoid
leaving the watch in the areas described below whenever charging its
rechargeable battery.
Also note that allowing the watch to become very hot can cause its liquid
crystal display to black out. The appearance of the LCD should become
normal again when the watch returns to a lower temperature.

Warning!
Leaving the watch in bright light to charge its rechargeable battery can
cause it to become quite hot. Take care when handling the watch to
avoid burn injury. The watch can become particularly hot when exposed
to the following conditions for long periods.

On the dashboard of a car parked in direct sunlight

Too close to an incandescent lamp

Under direct sunlight

Charging Guide

After a full charge, timekeeping remains enabled for up to about five months.

The following table shows the amount of time the watch needs to be
exposed to light each day in order to generate enough power for normal
daily operations.

Since these are the specs, we can include all the technical details.

6 minutes of time calibration reception per day

Display on 18 hours per day, sleep state 6 hours per day

1 illumination operation (1.5 seconds) per day

10 seconds of alarm operation per day

1 direction reading (20 seconds continuous measurement) per day

30 seconds of Barometric/Thermometer Mode measurements per day

Stable operation is promoted by frequent exposure to light.

Approximate

Exposure Time

5 minutes

24 minutes

48 minutes

8 hours

Exposure Level (Brightness)

Outdoor Sunlight (50,000 lux)

Sunlight Through a Window (10,000 lux)

Daylight Through a Window on a Cloudy Day (5,000 lux)

Indoor Fluorescent Lighting (500 lux)

Recovery Times

The table below shows the amount exposure that is required to take the
battery from one level to the next.

The above exposure time values are all for reference only. Actual required
exposure times depend on lighting conditions.

Approximate Exposure Time

Level 5

Level 4

Level 3

Level 2

Level 1

2 hours

13 hours

6 hours

4 hours

66 hours

30 hours

8 hours

134 hours

60 hours

83 hours

- - - - - -

- - - - - -

Exposure Level

(Brightness)

Outdoor Sunlight
(50,000 lux)

Sunlight Through a
Window (10,000 lux)

Daylight Through a
Window on a Cloudy
Day (5,000 lux)

Indoor Fluorescent
Lighting (500 lux)

Timekeeping

Use the Timekeeping Mode to view the current
time and date. You also need to enter the
Timekeeping Mode to configure timekeeping
settings, as well as the following settings.

Power saving on/off (“To turn Power Saving on
and off”)

Temperature unit (“To specify barometric
pressure and temperature units”)

Depth unit (“To specify the depth unit”)

Barometric pressure unit (“To specify
barometric pressure and temperature units”)

Hour : Minutes

PM indicator

Seconds

Day

Day of week

Setting the Time and Date Manually

Make sure you select your Home City code before you change the current
time and date settings. World Time Mode times are all displayed in
accordance with the Timekeeping Mode settings. Because of this, World Time
Mode times will not be correct if you do not select the proper Home City code
before setting the time and date in the Timekeeping Mode.

To set the time and date manually

1. In the Timekeeping Mode, hold down 

E

 until

the city code starts to flash, which indicates
the setting screen.

2. Press 

D

 to change the flashing contents in

the sequence shown below to select other
settings.

l l l

ll

ll

ll

ll

ll

ll

l l

l l l l

City
code

Seconds

Hour

12/24-Hour 
Format

Minutes

Year

DST

Month

Day

Power 
Saving

Temperature 

Unit

Barometric 

Pressure Unit

Depth 

Unit

City 

Code

Содержание 3047

Страница 1: ...or taking measurements that require professional or industrial precision Values produced by this watch should be considered as reasonable representations only When engaging in mountain climbing or other activities in which losing your way can create a dangerous or life threatening situation always be sure to use a second compass to confirm direction readings This watch is intended for use up to sk...

Страница 2: ...nal reception can be difficult or even impossible under the conditions listed below Inside or among buildings Inside a vehicle Near a construction site airport or other sources of electrical noise Near high tension power lines Among or behind mountains Near household appliances office equipment or a mobile phone The time calibration signal the watch will attempt to pick up depends on its current H...

Страница 3: ...t three minutes Note To interrupt a receive operation and return to the Receive Mode press C Receive failed If there was a previously successful reception If no reception was successful To turn auto receive on and off 1 Enter the Receive Mode 2 In the Receive Mode hold down E until the current auto receive setting ON or OFF starts to flash This is the setting screen Note that the setting screen wi...

Страница 4: ...45 inHg The barometric pressure value will be displayed again as soon as the measured barometric pressure is within the allowable range Temperature is displayed in units of 0 1 C or 0 2 F The displayed temperature value changes to C or F if a measured temperature falls outside the range of 10 0 C to 60 0 C 14 0 F to 140 0 F The temperature value will be displayed again as soon as the measured temp...

Страница 5: ...mum depth attained water temperature at maximum depth to be stored in log memory The elapsed time is displayed in minutes and seconds for the first hour After the first hour it switches to hours and minutes Pressing E while your current depth is less than one meter will toggle the display between the graph and the temperature screens If the watch stays at a depth of less than one meter and you do ...

Страница 6: ...at the water s surface never while the watch is submerged A major change in air temperature or other phenomena while you are using the Depth Gauge Mode can cause the display to show a value other than 0 meters feet when you are at the surface of the water If this happens reset the reference depth to 0 meters feet See To reset the reference depth to 0 meters feet manually for more information To vi...

Страница 7: ...e by pressing A while a timer operation is in progress The following describes what happens if you enter the Depth Gauge Mode for diving while a countdown operation is in progress Auto repeat off The alarm sounds when the end of the countdown is reached The progress beeper does not sound Auto repeat on Auto repeat timer alarm does not sound when the end of a countdown is reached The progress beepe...

Страница 8: ...easurement While a bearing sensor calibration operation is being performed in the Digital Compass Mode While a receive operation is in progress in the Receive Mode Moving the watch to a position that is parallel to the ground and then tilting it towards you more than 40 degrees causes illumination to turn on Wear the watch on the outside of your wrist Warning Always make sure you are in a safe pla...

Страница 9: ... watch to become very hot Avoid leaving the watch in the areas described below whenever charging its rechargeable battery Also note that allowing the watch to become very hot can cause its liquid crystal display to black out The appearance of the LCD should become normal again when the watch returns to a lower temperature Warning Leaving the watch in bright light to charge its rechargeable battery...

Страница 10: ...e turned off automatically Transmitter area city codes HKG SEL and TYO LAX DEN CHI NYC ANC and HNL LON PAR BER and ATH All other city codes Reference This section contains more detailed and technical information about watch operation It also contains important precautions and notes about the various features and functions of this watch Auto Return Features The watch will return to the Timekeeping ...

Страница 11: ...ka Saga When a European time zone is selected the watch receives the time calibration signals transmitted from Germany Mainflingen and England Rugby The following tables show the reception priority for the European signals When PAR BER or ATH is selected as the Home City code When LON is selected as the Home City code In this case The first signal search operation after the Home City code has been...

Страница 12: ...es at the 6 o clock position when calibration of the first direction is complete This means that the watch is ready for calibration of the second direction 4 Rotate the watch 180 degrees l l l l l l l l l l l l l l l l l l 5 Press A again to calibrate the second direction xxx is shown on the display while calibration is being performed When calibration is complete OK appears and then the Digital C...

Страница 13: ...e Important This resets the reference depth and causes the displayed depth to change to 0 meters feet Never perform the above operation while submerged To specify the depth unit 1 Enter the Timekeeping Mode 2 Hold down E until the city code starts to flash which indicates the setting screen 3 Press D 11 times to select the depth unit setting See step 2 under To set the time and date manually for i...

Отзывы: