Casio 3047 Скачать руководство пользователя страница 4

Operation Guide 3047

4

To take a direction reading

1. Enter the Digital Compass Mode.
2. Place the watch on a flat surface or, if you are

wearing the watch, make sure that your wrist
is horizontal (in relation to the horizon).

3. Point the 12 o’clock position of the watch in

the direction you want to measure.

4. Press 

A

 to start a Digital Compass

measurement operation.

After about two seconds, the direction that the
12 o’clock position of the watch is pointing
appears on the display.

Also, four pointers appear to indicate magnetic
north, south, east, and west.

After the first reading is obtained, the watch
continues to take direction readings
automatically each second, for up to 20
seconds.

Direction
indicator

Angle value (in degrees)

Magnetic north pointer

12 o’clock position

NW

0

°

WNW

W

W

S

W

SW

S

S

W

S

SSE

SE

ES

E

E

E

N

E

NE

N

N

E

N

NNW

During measurement, the watch displays an angle value, a direction
indicator, and four direction pointers, which change dynamically when the
watch is moved. After measurement is complete, the angle value,
direction indicator, and four direction pointers are frozen in accordance
with the last measurement.

Note

Note that taking a measurement
while the watch is not horizontal
(in relation to the horizon) can
result in large measurement error.

The margin of error for the angle value is 

±

11 degrees. If the indicated

direction is northwest (

NW

) and 315 degrees, for example, the actual

direction can be anywhere from 304 to 326 degrees.

See “Digital Compass Precautions” for other important information about
taking direction readings.

Any ongoing direction measurement operation is paused temporarily while
the watch is performing an alert operation (daily alarm, Hourly Time Signal,
countdown timer alarm) or while the watch illuminates the display (by
pressing 

L

). The measurement operation resumes for its remaining

duration after the operation that caused it to pause is finished.

The following table shows the meanings of each of the direction
abbreviations that appear on the display.

Direction Meaning

Direction

Meaning

Direction

Meaning

Direction

Meaning

NNE

ESE

SSW

WNW

NE

SE

SW

NW

North-

northeast

East-

southeast

South-

southwest

West-

northwest

Northeast

Southeast

Southwest

Northwest

East-

northeast

South-

southeast

West-

southwest

North-

northwest

ENE

SSE

WSW

NNW

North

East

South

West

N

E

S

W

Barometer/Thermometer

This watch uses a pressure sensor to measure air pressure (barometric
pressure) and a temperature sensor to measure temperature.

You can calibrate the temperature sensor and the pressure sensor if you
suspect that readings are incorrect.

To take barometric pressure and temperature readings

Pressing 

B

 in the Timekeeping or Digital Compass Mode enters the

Barometer/Thermometer Mode and starts taking barometric pressure and
temperature measurements automatically.

Press 

E

 to

toggle between
screens.

History Graph and
Barometric Pressure

History graph

Temperature

Barometric
pressure

Temperature and
Barometric Pressure

It can take up to four or five seconds for the barometric pressure reading to
appear after you enter the Barometer/Thermometer Mode.

Barometric pressure is displayed in units of 1hPa (or 0.05 inHg).

The displayed barometric pressure value changes to 

xxxx

 hPa (or inHg) if

a measured barometric pressure falls outside the range of 600 hPa to 1100
hPa (17.70 inHg to 32.45 inHg). The barometric pressure value will be
displayed again as soon as the measured barometric pressure is within the
allowable range.

Temperature is displayed in units of 0.1

°

C (or 0.2

°

F).

The displayed temperature value changes to 

---

.

 

-

 

°

C (or 

°

F) if a

measured temperature falls outside the range of –10.0

°

C to 60.0

°

C (14.0

°

F

to 140.0

°

F). The temperature value will be displayed again as soon as the

measured temperature is within the allowable range.

In some areas, barometric pressure is expressed in millibars (mb) instead
of hecto-pascals (hPa). It really makes no difference, because 1hPa = 1mb.

You can select either hectopascals (hPa) or inchesHg (inHg) as the display
unit for the measured barometric pressure, and Celsius  (

°

C)  or Fahrenheit

(

°

F) as the display unit for the measured temperature value. See “To specify

barometric pressure and temperature units”.

See “Barometer and Thermometer Precautions” for important precautions.

Barometric Pressure Graph

Barometric pressure indicates changes in the atmosphere. By monitoring
these changes you can predict the weather with reasonable accuracy.
In every mode except for the Depth Gauge Mode, your watch takes barometric
pressure readings every two hours (at the top of each even-numbered hour).
Measurement results are used to produce barometric pressure graph and
barometric pressure differential pointer readings.
The barometric pressure graph shows readings of previous measurements for
up to 30 hours. The horizontal axis of the graph represents time, with each
dot standing for two hours. The rightmost dot (flashing) represents the most
recent reading. The vertical axis of the graph represents barometric pressure,
with each dot standing for the relative difference between its reading and that
of the dots next to it. Each dot represents 1hPa.
The following shows how to interpret the data that appears on the barometric
pressure graph.

A rising graph generally means improving weather.

A falling graph generally means deteriorating weather.

Note that if there are sudden changes in weather or
temperature, the graph line of past measurements may run
off the top or bottom of the display. The entire graph will
become visible once barometric conditions stabilize.
The following conditions cause the barometric pressure
measurement to be skipped, with the corresponding point on
the barometric pressure graph being left blank.

Barometric reading that is out of range (600 hPa/mb to 1,100 hPa/mb or
17.70 inHg to 32.45 inHg)

Sensor malfunction

Not visible on
the display.

Barometric Pressure Differential Pointer

This pointer indicates the relative difference between the most recent
barometric pressure reading indicated on the barometric pressure graph, and
the current barometric pressure value displayed in the Barometer/
Thermometer Mode.

Pressure differential is indicated in the range of 

±

15 hPa, in 1-hPa units.

The barometric pressure differential pointer is not displayed when the
displayed current barometric value is outside of the allowable measurement
range (600 to 1,100 hPa).

Barometric pressure is calculated and displayed using hPa as the standard.
The barometric pressure differential also can be read in inHg units as
shown in the illustration.

Pressure differential
examples in the
illustration are indicated
in 10 hPa/0.3 inHg
steps.

Current pressure
less than most
recent measured
pressure

Points to 3 o’clock for
differentials outside
the range of 

±

15 hPa/

±

0.44 inHg.

Current pressure
greater than most
recent measured
pressure

Barometric pressure
differential pointer

inHg values

hPa values

Содержание 3047

Страница 1: ...or taking measurements that require professional or industrial precision Values produced by this watch should be considered as reasonable representations only When engaging in mountain climbing or other activities in which losing your way can create a dangerous or life threatening situation always be sure to use a second compass to confirm direction readings This watch is intended for use up to sk...

Страница 2: ...nal reception can be difficult or even impossible under the conditions listed below Inside or among buildings Inside a vehicle Near a construction site airport or other sources of electrical noise Near high tension power lines Among or behind mountains Near household appliances office equipment or a mobile phone The time calibration signal the watch will attempt to pick up depends on its current H...

Страница 3: ...t three minutes Note To interrupt a receive operation and return to the Receive Mode press C Receive failed If there was a previously successful reception If no reception was successful To turn auto receive on and off 1 Enter the Receive Mode 2 In the Receive Mode hold down E until the current auto receive setting ON or OFF starts to flash This is the setting screen Note that the setting screen wi...

Страница 4: ...45 inHg The barometric pressure value will be displayed again as soon as the measured barometric pressure is within the allowable range Temperature is displayed in units of 0 1 C or 0 2 F The displayed temperature value changes to C or F if a measured temperature falls outside the range of 10 0 C to 60 0 C 14 0 F to 140 0 F The temperature value will be displayed again as soon as the measured temp...

Страница 5: ...mum depth attained water temperature at maximum depth to be stored in log memory The elapsed time is displayed in minutes and seconds for the first hour After the first hour it switches to hours and minutes Pressing E while your current depth is less than one meter will toggle the display between the graph and the temperature screens If the watch stays at a depth of less than one meter and you do ...

Страница 6: ...at the water s surface never while the watch is submerged A major change in air temperature or other phenomena while you are using the Depth Gauge Mode can cause the display to show a value other than 0 meters feet when you are at the surface of the water If this happens reset the reference depth to 0 meters feet See To reset the reference depth to 0 meters feet manually for more information To vi...

Страница 7: ...e by pressing A while a timer operation is in progress The following describes what happens if you enter the Depth Gauge Mode for diving while a countdown operation is in progress Auto repeat off The alarm sounds when the end of the countdown is reached The progress beeper does not sound Auto repeat on Auto repeat timer alarm does not sound when the end of a countdown is reached The progress beepe...

Страница 8: ...easurement While a bearing sensor calibration operation is being performed in the Digital Compass Mode While a receive operation is in progress in the Receive Mode Moving the watch to a position that is parallel to the ground and then tilting it towards you more than 40 degrees causes illumination to turn on Wear the watch on the outside of your wrist Warning Always make sure you are in a safe pla...

Страница 9: ... watch to become very hot Avoid leaving the watch in the areas described below whenever charging its rechargeable battery Also note that allowing the watch to become very hot can cause its liquid crystal display to black out The appearance of the LCD should become normal again when the watch returns to a lower temperature Warning Leaving the watch in bright light to charge its rechargeable battery...

Страница 10: ...e turned off automatically Transmitter area city codes HKG SEL and TYO LAX DEN CHI NYC ANC and HNL LON PAR BER and ATH All other city codes Reference This section contains more detailed and technical information about watch operation It also contains important precautions and notes about the various features and functions of this watch Auto Return Features The watch will return to the Timekeeping ...

Страница 11: ...ka Saga When a European time zone is selected the watch receives the time calibration signals transmitted from Germany Mainflingen and England Rugby The following tables show the reception priority for the European signals When PAR BER or ATH is selected as the Home City code When LON is selected as the Home City code In this case The first signal search operation after the Home City code has been...

Страница 12: ...es at the 6 o clock position when calibration of the first direction is complete This means that the watch is ready for calibration of the second direction 4 Rotate the watch 180 degrees l l l l l l l l l l l l l l l l l l 5 Press A again to calibrate the second direction xxx is shown on the display while calibration is being performed When calibration is complete OK appears and then the Digital C...

Страница 13: ...e Important This resets the reference depth and causes the displayed depth to change to 0 meters feet Never perform the above operation while submerged To specify the depth unit 1 Enter the Timekeeping Mode 2 Hold down E until the city code starts to flash which indicates the setting screen 3 Press D 11 times to select the depth unit setting See step 2 under To set the time and date manually for i...

Отзывы: