4

To take a direction reading

1. While the watch is in the Digital Compass

Mode, place it on a flat surface, or if you are
wearing the watch, make sure that your wrist
is horizontal (in relation to the horizon).

2. Point the 12 o’clock position of the watch in

the direction you want to measure.

3. Press 

A

 to start a Digital Compass

measurement operation.

After about two seconds, the direction that the
12 o’clock position of the watch is pointing
appears on the display.

Also, four pointers appear to indicate magnetic
north, south, east, and west.

After the first reading is obtained, the watch
continues to take direction readings
automatically each second, for up to 20
seconds.

Direction
indicator

Angle value (in degrees)

Magnetic north pointer

12 o’clock position

NW

0

°

WN

W

W

W

S

W

SW

S

S

W

S

SSE

SE

ES

E

E

ENE

NE

N

N

E

N

NNW

90

°

180

°

270

°

During measurement, the watch displays an angle value, a direction
indicator, and four direction pointers, which change dynamically when the
watch is moved. After measurement is complete, the angle value,
direction indicator, and four direction pointers are frozen in accordance
with the last measurement.

The 

ACT

 indicator flashes on the display while a measurement is in

progress.

Note

Note that taking a measurement
while the watch is not horizontal
(in relation to the horizon) can
result in large measurement error.

The margin of error for the angle value is ±11 degrees. If the indicated
direction is northwest (

NW

) and 315 degrees, for example, the actual

direction can be anywhere from 304 to 326 degrees.

Any ongoing direction measurement operation is paused temporarily while
the watch is performing an alert operation (daily alarm, Hourly Time Signal,
countdown timer alarm) or while illumination is turned on (by pressing 

L

).

The measurement operation resumes for its remaining duration after the
operation that caused it to pause is finished.

The following table shows the meanings of each of the direction
abbreviations that appear on the display.

See “Digital Compass Precautions” for other important information about
taking direction readings.

Direction Meaning

Direction

Meaning

Direction

Meaning

Direction

Meaning

NNE

ESE

SSW

WNW

NE

SE

SW

NW

North-

northeast

East-

southeast

South-

southwest

West-

northwest

Northeast

Southeast

Southwest

Northwest

East-

northeast

South-

southeast

West-

southwest

North-

northwest

ENE

SSE

WSW

NNW

North

East

South

West

N

E

S

W

Barometer/Thermometer

This watch uses a pressure sensor to measure air pressure (barometric
pressure) and a temperature sensor to measure temperature.

You can calibrate the pressure sensor and the temperature sensor if you
suspect that readings are incorrect.

To take barometric pressure and temperature readings

Pressing 

B

 in the Timekeeping Mode or in any

of other sensor modes enters the Barometer/
Thermometer Mode and starts barometric
pressure and temperature measurements
automatically .

It can take up to four or five seconds for the
barometric pressure reading to appear after
you enter the Barometer/Thermometer Mode.

Barometric pressure is displayed in units of
1hPa (or 0.05 inHg).

Temperature

Barometric
pressure

Barometric
pressure graph

Pressure
differential
pointer

The displayed barometric pressure value changes to 

xxxx

 hPa (or inHg) if

a measured barometric pressure falls outside the range of 260 hPa to
1100 hPa (7.65 inHg to 32.45 inHg). The barometric pressure value will
reappear as soon as the measured barometric pressure is within the
allowable range.

Temperature is displayed in units of 0.1°C (or 0.2°F).

The displayed temperature value changes to 

xxx

 °C (or °F) if a measured

temperature falls outside the range of –10.0°C to 60.0°C (14.0°F to
140.0°F). The temperature value will reappear as soon as the measured
temperature is within the allowable range.

In some areas, barometric pressure is expressed in millibars (mb) instead
of hectopascals (hPa). It really makes no difference, because 1hPa = 1mb.

You can select either hectopascals (hPa) or inchesHg (inHg) as the display
unit for the measured barometric pressure, and Celsius  (°C)  or Fahrenheit
(°F) as the display unit for the measured temperature value. See “To select
the temperature, barometric pressure, and altitude units”.

See “Barometer and Thermometer Precautions” for important precautions.

Barometric Pressure Graph

Barometric pressure indicates changes in the atmosphere. By monitoring
these changes you can predict the weather with reasonable accuracy.
This watch takes barometric pressure measurements automatically every two
hours (at the top of each even-numbered hour), regardless of its current
mode. Measurement results are used to produce barometric pressure graph
and barometric pressure differential pointer readings.
The barometric pressure graph shows readings of previous measurements for
up to 30 hours. The horizontal axis of the graph represents time, with each dot
standing for two hours. The rightmost dot represents the most recent reading.
The vertical axis of the graph represents barometric pressure, with each dot
standing for the relative difference between its reading and that of the dots
next to it. Each dot represents 1hPa.
The following shows how to interpret the data that appears on the barometric
pressure graph.

A rising graph generally means improving weather.

A falling graph generally means deteriorating weather.

Note that if there are sudden changes in weather or
temperature, the graph line of past measurements may run
off the top or bottom of the display. The entire graph will
become visible once barometric conditions stabilize.
The following conditions cause the barometric pressure
measurement to be skipped, with the corresponding point on
the barometric pressure graph being left blank.

Barometric reading that is out of range (260 hPa/mb to 1,100 hPa/mb or
7.65 inHg to 32.45 inHg)

Sensor malfunction

Not visible on
the display.

Barometric Pressure Differential Pointer

This pointer indicates the relative difference between the most recent
barometric pressure reading indicated on the barometric pressure graph, and
the current barometric pressure value displayed in the Barometer/
Thermometer Mode.

Pressure differential is indicated in the range of ±15 hPa, in 1-hPa units.

The barometric pressure differential pointer is not displayed when the
displayed current barometric value is outside of the allowable measurement
range (260 to 1,100 hPa).

Barometric pressure is calculated and displayed using hPa as the standard.
The barometric pressure differential can also be read in inHg units as
shown in the illustration.

Pressure differential
examples in the
illustration are indicated
in 10 hPa/0.3 inHg
steps.

Current pressure
less than most
recent measured
pressure

Points to 9 o’clock for
differentials outside
the range of ±15 hPa/
±0.44 inHg.

Current pressure
greater than most
recent measured
pressure

Barometric pressure
differential pointer

inHg values

hPa values

Содержание 3043

Страница 1: ... more information Warning The measurement functions built into this watch are not intended for taking measurements that require professional or industrial precision Values produced by this watch should be considered as reasonable representations only When engaging in mountain climbing or other activities in which losing your way can create a dangerous or life threatening situation always be sure t...

Страница 2: ...nal reception can be difficult or even impossible under the conditions listed below Inside or among buildings Inside a vehicle Near a construction site airport or other sources of electrical noise Near high tension power lines Among or behind mountains Near household appliances office equipment or a mobile phone Signal reception normally is better at night than during the day Time calibration sign...

Страница 3: ...viously successful reception If no reception was successful To turn auto receive on and off 1 Enter the Receive Mode 2 In the Receive Mode hold down E until the current auto receive setting ON or OFF starts to flash This is the setting screen Note that the setting screen will not appear if the currently selected Home City is one that does not support time calibration reception 3 Press C to toggle ...

Страница 4: ...Pa 7 65 inHg to 32 45 inHg The barometric pressure value will reappear as soon as the measured barometric pressure is within the allowable range Temperature is displayed in units of 0 1 C or 0 2 F The displayed temperature value changes to xxx C or F if a measured temperature falls outside the range of 10 0 C to 60 0 C 14 0 F to 140 0 F The temperature value will reappear as soon as the measured t...

Страница 5: ...y the watch will be more accurate than they would without a reference altitude 400 B A Displaying Your Current Altitude You can use the procedure described in this section to display your current altitude If you leave the watch in the Altimeter Mode it will update the displayed altitude value regularly and indicate reading to reading changes in the altitude graph at the top of the display Importan...

Страница 6: ...own C for about one second until REC disappears from the screen You can recall saved records using the Data Recall Mode Other Altimeter Mode Features This section explains other features and settings that are available in the Altimeter Mode Note that all of the information in this section applies to all types of Altimeter Mode measurements unless specifically indicated otherwise Specifying a Refer...

Страница 7: ...rds show only data for the last save session performed with the watch There can be up to 40 periodic records in memory Historical Record The historical record shows data for all save sessions performed since the last time the historical record was cleared To view periodic records and current session record contents 1 Enter the Data Recall Mode 2 Use C and A to scroll through the data and display t...

Страница 8: ...an set a countdown start time in the range of one minute to 60 minutes in one minute increments Auto repeat Whenever zero is reached the watch beeps and auto repeat automatically restarts the countdown from the countdown start time you set When the countdown reaches zero while auto repeat is turned off the watch will beep and then display the countdown start time without restarting the countdown A...

Страница 9: ...the auto light switch on A EL displayed and off A EL not displayed The auto light switch on indicator A EL is on the display in all modes while the auto light switch is turned on The auto light switch turns off automatically whenever battery power drops to Level 4 Illumination may not turn on right away if you raise the watch to your face while a barometric pressure or altitude measurement operati...

Страница 10: ...way that it is blocked from exposure to light can cause rechargeable battery power to run down Be sure that the watch is exposed to bright light whenever possible This watch uses a special rechargeable battery to store power produced by the solar cell so regular battery replacement is not required However after very long use the rechargeable battery may lose its ability to achieve a full charge If...

Страница 11: ...code For more information see Daylight Saving Time DST below You also need to enter the Timekeeping Mode in order to configure the following settings Display illumination duration To specify the illumination duration Power saving on off To turn Power Saving on and off Temperature barometric pressure and altitude units To select the temperature barometric pressure and altitude units Daylight Saving...

Страница 12: ...e Timekeeping Mode hold down E until the city code starts to flash which indicates the setting screen 2 Press D nine times until the Power Saving on off screen appears 3 Press C to toggle Power Saving on ON and off OFF 4 Press E to exit the setting screen The Power Saving on indicator PS is on the display in all modes while Power Saving is turned on l l l l l l l l l l l l l l l l l Power Saving o...

Страница 13: ...ntrations of metal metal doors lockers etc high tension wires aerial wires household appliances TVs personal computers washing machines freezers etc Accurate direction readings are impossible while in a train boat air plane etc Accurate readings are also impossible indoors especially inside ferro concrete structures This is because the metal framework of such structures picks up magnetism from app...

Страница 14: ...OFF or the current reference temperature value if set starts to flash This is the setting screen If you want to calibrate the barometric pressure sensor press D to move the flashing to the middle display area This is the pressure sensor calibration screen At this time OFF or the barometric pressure value should be flashing on the display l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l ...

Отзывы: