Casio 3043 Скачать руководство пользователя страница 12

Operation Guide 3043

12

Reference

This section contains more detailed and technical information about watch
operation. It also contains important precautions and notes about the various
features and functions of this watch.

Auto Return Features

The watch returns to the Timekeeping Mode automatically if you do not
perform any button operation for two or three minutes in the Data Recall,
Alarm, Receive, Digital Compass, or Barometer/Thermometer Mode.

If you do not perform any button operation while in the Altimeter Mode, the
watch returns to the Timekeeping Mode automatically after nine or 10
hours.

If you leave a screen with flashing digits on the display for two or three
minutes without performing any operation, the watch exits the setting
screen automatically.

Scrolling

The 

A

 and 

C

 buttons are used on the setting screen to scroll through data

on the display. In most cases, holding down these buttons during a scroll
operation scrolls through the data at high speed.

Sensor Malfunction Indicator

Subjecting the watch to strong impact can cause sensor malfunction or
improper contact of internal circuitry. When this happens, 

ERR

 (error) will

appear on the display and sensor operations will be disabled.

Barometric

 Pressure

Measurement

Digital

Compass

Measurement

Altitude

Measurement

If 

ERR

 appears while a measurement operation is being performed in a

sensor mode, restart the measurement. If 

ERR

 appears on the display

again, it can mean there is something wrong with the sensor.

Even if battery power is at Level 1 or Level 2, the Digital Compass Mode,
Barometer/Thermometer Mode, or Altimeter Mode sensor may be disabled
if there is not enough voltage available to power it sufficiently. In this case,

ERR

 will appear on the display. This does not indicate malfunction, and

sensor operation should resume once battery voltage returns to its normal
level.

If 

ERR

 keeps appearing during measurement, it could mean there is a

problem with the applicable sensor.

Whenever you have a sensor malfunction, be sure to take the watch to
your original dealer or nearest authorized CASIO distributor as soon as
possible.

Power Saving

When turned on, Power Saving enters a sleep
state automatically whenever the watch is left for
a certain period in an area where it is dark. The
table below shows how watch functions are
affected by Power Saving.

There are actually two sleep state levels:
“display sleep” and “function sleep”.

Elapsed Time  in

Dark

60 to 70 minutes

(Display Sleep)

6 or 7 days

(Function Sleep)

Display

Blank, with

PS 

flashing

Blank, with

PS 

not flashing

Operation

Display is off, but all functions are
enabled.

All functions are disabled, but
timekeeping is maintained.

Wearing the watch inside the sleeve of clothing can cause it to enter the
sleep state.

The watch will not enter the sleep state while the digital time is between
6:00 AM and 9:59 PM. If the watch is already in the sleep state when the
digital time reaches 6:00 AM, however, it will remain in the sleep state.

The watch will not enter the sleep state while it is in the Digital Compass,
Barometer/Thermometer, Altimeter, Receive, Countdown Timer, or
Stopwatch Mode. When the watch is left in any mode besides the
Countdown Timer and Stopwatch Mode, the watch will return to the
Timekeeping Mode automatically after a specific amount of time. Then if left
in the dark for the elapsed time indicated in the table above, the watch will
enter the sleep state.

To recover from the sleep state

Perform any one of the following operations.

Move the watch to a well-lit area. It can take up to two seconds for the
display to turn on.

Press any button.

Angle the watch towards your face for reading.

To turn Power Saving on and off

1. In the Timekeeping Mode, hold down 

E

 until

the city code starts to flash, which indicates
the setting screen.

2. Press 

D

 nine times until the Power Saving

on/off screen appears.

3. Press 

C

 to toggle Power Saving on (

ON

) and

off (

OFF

).

4. Press 

to exit the setting screen.

The Power Saving on indicator (

PS

) is on the

display in all modes while Power Saving is
turned on.

l

l

l

l l

l l l l l

l

l

ll

ll

l

Power Saving on
indicator

Radio-controlled Atomic Timekeeping Precautions

Strong electrostatic charge can result in the wrong time being set.

The time calibration signal bounces off the ionosphere. Because of this,
such factors as changes in the reflectivity of the ionosphere, as well as
movement of the ionosphere to higher altitudes due to seasonal
atmospheric changes or the time of day may change the reception range of
the signal and make reception temporarily impossible.

Even if the time calibration signal is received properly, certain conditions
can cause the time setting to be off by up to one second.

The current time setting in accordance with the time calibration signal takes
priority over any time settings you make manually.

The watch is designed to update the date and day of the week
automatically for the period January 1, 2001 to December 31, 2099. Setting
of the date by the time calibration signal cannot be performed starting from
January 1, 2100.

This watch can receive signals that differentiate between leap years and
non-leap years.

Though this watch is designed to receive both time data (hour, minutes,
seconds) and date data (year, month, day), certain signal conditions can
limit reception to time data only.

If you are in an area where proper time calibration signal reception is
impossible, the watch keeps time within ±15 seconds a month at normal
temperature.

If you have problems with proper time calibration signal reception or if the
time setting is wrong after signal reception, check your current city code,
DST (summer time), and auto receive settings.

The Home City setting reverts to the initial default of 

BER

 (Berlin)

whenever the battery power level drops to Level 5 or when you have the
rechargeable battery replaced. If this happens, change the Home City to
the setting you want.

Transmitters

The time calibration signal received by this watch depends on the currently
selected Home City code.

When a U.S. time zone is selected, the watch receives the time calibration
signal transmitted from the United States (Fort Collins).

When a Japanese time zone is selected, the watch receives the time
calibration signal transmitted from the Japan (Fukushima and Fukuoka/
Saga).

When a European time zone is selected, the watch receives the time
calibration signals transmitted from Germany (Mainflingen) and England
(Rugby). The following tables show the reception priority for the European
signals.

When PAR, BER, or ATH is selected as the Home City code:

When LON is selected as the Home City code:

In this case:

The first signal search
operation after the Home City
code has been changed

The second and
subsequent signal searches

The watch does this:

1. Checks the Mainflingen signal first.
2. If the Mainflingen signal cannot be

received, checks the Rugby signal.

1. Checks the signal of the transmitter of the first

receive operation (Rugby or Mainflingen).

2. If the checked signal cannot be received,

checks the other signal.

The watch does this:

1. Checks the Rugby signal first.
2. If the Rugby signal cannot be received,

checks the Mainflingen signal.

1. Checks the signal of the transmitter of the first

receive operation (Rugby or Mainflingen).

2. If the checked signal cannot be received,

checks the other signal.

In this case:

The first signal search
operation after the Home City
code has been changed

The second and
subsequent signal searches

4. When the setting you want is selected, press 

E

 to exit the setting screen.

 The 

DST

 indicator appears to indicate that Daylight Saving Time is turned

on.

Содержание 3043

Страница 1: ... more information Warning The measurement functions built into this watch are not intended for taking measurements that require professional or industrial precision Values produced by this watch should be considered as reasonable representations only When engaging in mountain climbing or other activities in which losing your way can create a dangerous or life threatening situation always be sure t...

Страница 2: ...nal reception can be difficult or even impossible under the conditions listed below Inside or among buildings Inside a vehicle Near a construction site airport or other sources of electrical noise Near high tension power lines Among or behind mountains Near household appliances office equipment or a mobile phone Signal reception normally is better at night than during the day Time calibration sign...

Страница 3: ...viously successful reception If no reception was successful To turn auto receive on and off 1 Enter the Receive Mode 2 In the Receive Mode hold down E until the current auto receive setting ON or OFF starts to flash This is the setting screen Note that the setting screen will not appear if the currently selected Home City is one that does not support time calibration reception 3 Press C to toggle ...

Страница 4: ...Pa 7 65 inHg to 32 45 inHg The barometric pressure value will reappear as soon as the measured barometric pressure is within the allowable range Temperature is displayed in units of 0 1 C or 0 2 F The displayed temperature value changes to xxx C or F if a measured temperature falls outside the range of 10 0 C to 60 0 C 14 0 F to 140 0 F The temperature value will reappear as soon as the measured t...

Страница 5: ...y the watch will be more accurate than they would without a reference altitude 400 B A Displaying Your Current Altitude You can use the procedure described in this section to display your current altitude If you leave the watch in the Altimeter Mode it will update the displayed altitude value regularly and indicate reading to reading changes in the altitude graph at the top of the display Importan...

Страница 6: ...own C for about one second until REC disappears from the screen You can recall saved records using the Data Recall Mode Other Altimeter Mode Features This section explains other features and settings that are available in the Altimeter Mode Note that all of the information in this section applies to all types of Altimeter Mode measurements unless specifically indicated otherwise Specifying a Refer...

Страница 7: ...rds show only data for the last save session performed with the watch There can be up to 40 periodic records in memory Historical Record The historical record shows data for all save sessions performed since the last time the historical record was cleared To view periodic records and current session record contents 1 Enter the Data Recall Mode 2 Use C and A to scroll through the data and display t...

Страница 8: ...an set a countdown start time in the range of one minute to 60 minutes in one minute increments Auto repeat Whenever zero is reached the watch beeps and auto repeat automatically restarts the countdown from the countdown start time you set When the countdown reaches zero while auto repeat is turned off the watch will beep and then display the countdown start time without restarting the countdown A...

Страница 9: ...the auto light switch on A EL displayed and off A EL not displayed The auto light switch on indicator A EL is on the display in all modes while the auto light switch is turned on The auto light switch turns off automatically whenever battery power drops to Level 4 Illumination may not turn on right away if you raise the watch to your face while a barometric pressure or altitude measurement operati...

Страница 10: ...way that it is blocked from exposure to light can cause rechargeable battery power to run down Be sure that the watch is exposed to bright light whenever possible This watch uses a special rechargeable battery to store power produced by the solar cell so regular battery replacement is not required However after very long use the rechargeable battery may lose its ability to achieve a full charge If...

Страница 11: ...code For more information see Daylight Saving Time DST below You also need to enter the Timekeeping Mode in order to configure the following settings Display illumination duration To specify the illumination duration Power saving on off To turn Power Saving on and off Temperature barometric pressure and altitude units To select the temperature barometric pressure and altitude units Daylight Saving...

Страница 12: ...e Timekeeping Mode hold down E until the city code starts to flash which indicates the setting screen 2 Press D nine times until the Power Saving on off screen appears 3 Press C to toggle Power Saving on ON and off OFF 4 Press E to exit the setting screen The Power Saving on indicator PS is on the display in all modes while Power Saving is turned on l l l l l l l l l l l l l l l l l Power Saving o...

Страница 13: ...ntrations of metal metal doors lockers etc high tension wires aerial wires household appliances TVs personal computers washing machines freezers etc Accurate direction readings are impossible while in a train boat air plane etc Accurate readings are also impossible indoors especially inside ferro concrete structures This is because the metal framework of such structures picks up magnetism from app...

Страница 14: ...OFF or the current reference temperature value if set starts to flash This is the setting screen If you want to calibrate the barometric pressure sensor press D to move the flashing to the middle display area This is the pressure sensor calibration screen At this time OFF or the barometric pressure value should be flashing on the display l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l ...

Отзывы: