background image

IOM-DA0

10

SECTION X

NEW REPLACEMENT UNIT:

Contact your local Cashco, Inc., Sales Rep re sen-
 ta tive with the Serial Number and Product code.  
With this information they can provide a quotation 
for a new unit including a complete description, 
price and availability.

7

X. ORDERING INFORMATION
 

 

NEW REPLACEMENT UNIT vs PARTS  "KIT" FOR FIELD REPAIR 

To obtain a quotation or place an order, please retrieve the Serial Number and Product Code that was stamped on 
the metal name plate and attached to the unit. This information can also be found on the Bill of Material ("BOM"), 
a parts list that was provided when unit was originally shipped. (Serial Number typically 6 digits). Product Code 
typical format as follows:  (last digit is alpha character that reflects revision level for the product).

PARTS "KIT" for FIELD REPAIR:

Contact your local Cashco, Inc., Sales Rep re sen-
 ta tive with the Serial Number and Product code.  
Identify the parts and the quantity required to repair 
the unit from the "BOM" sheet that was provided 
when unit was originally shipped. 

NOTE:

 

  Those part numbers that have a quantity indicated 

under  "Spare Parts" in column "A” reflect minimum 
parts required for inspection and rebuild, - "Soft 
Goods Kit". Those in column “B” include minimum 
trim replacement parts needed plus those "Soft 
Goods" parts from column "A".

If the "BOM" is not available, refer to the cross-
sectional drawings included in this manual for part 
identification and selection.

A Local Sales Representative will provide quotation 
for appropriate Kit Number, Price and Availability.

          CAUTION

Do not attempt to alter the original construction of any 
unit without assistance and approval from the factory.  
All purposed changes will require a new name plate 
with appropriate ratings and new product code to 
accommodate the recommended part(s) changes.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be 

construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability.  We reserve the right to 

modify or improve the designs or specifications of such product at any time without notice.

Cashco, Inc. does not assume responsibility for the selection, use or maintenance of any product.  Responsibility for proper selection, use and maintenance of any 

Cashco, Inc. product remains solely with the purchaser.

Содержание DA0

Страница 1: ...pical pipelinedebrisfromenteringvalveanddamaging internal soft goods primarily the dynamic seal 4 Steam traps should be installed before and after the regulator to provide proper drainage 5 Install th...

Страница 2: ...not over pressurizing 6 Continue to slowly open the inlet upstream block valve until fully open 7 Continue to slowly open the outlet downstream block valve especially when the downstream pip ing syste...

Страница 3: ...nance while in line VII MAINTENANCE A General Item No Part Description 7 Nut 10 Stop Plate 13 Guide Bearing Piston 14 Lower and Upper Static Stem Seal 15 Cage O ring Seal 16 Wiper 17 Wiper Washer 19 C...

Страница 4: ...sembly of the ITA 1 To disassemble the ITA hold the lower part of the plug 20 in a bench vise Do not hold on the machined surface in the plug s 20 spindle area NOTE The spindle slides in Figure 2 Asse...

Страница 5: ...r seal 16 is best left in this position overnight minimum of two 2 hours prior to final reassembly 2 After re forming the wiper seal remove parts 13 16 17 from cage 19 and disassemble this temporary a...

Страница 6: ...eplate 99 located under one bolt head 9 Tighten the body bolting 11 12 evenly in an alternating cross pattern in one revolution increments to the following torque values G Pressure Testing 1 If a hydr...

Страница 7: ...e path may be via plug seat or dynamic side seal 3 Pressure Containment Test a Pressurize inlet to 200 psig 13 8 Barg and outlet and cover dome to 150 psig 10 3 Barg with air or GN2 b Spray liquid lea...

Страница 8: ...07 4 10 28 6 9 6 41 4 28 SIZE ORIENTATION S O Factor Body Size in DN Orientation Cover Dome on Top Cover Dome on Bottom 1 2 1 15 25 1 1 1 1 4 1 1 2 32 40 2 2 2 50 2 5 2 5 2 1 2 3 65 80 3 3 4 100 4 4...

Страница 9: ...nd if necessary replace B Oversized regulator B Check actual flow conditions resize regulator for minimum and maxi mum flow if necessary replace with smaller size regulator 2 Downstream pressure will...

Страница 10: ...A reflectminimum parts required for inspection and rebuild Soft Goods Kit Those in column B include minimum trim replacement parts needed plus those Soft Goods parts from column A If the BOM is not av...

Страница 11: ...uide Bearing 14 Seal 15 Cage Seal 16 Wiper Seal 17 Washer 18 Cage Cap Screws 19 Cage Item No Description 20 Plug 21 Seat 22 Spring 23 Body 24 Body Bushing 25 Cover Dome 27 Dynamic Seal see Figure 1 37...

Страница 12: ...ooling of the process gas depends on the process gas and the inlet and outlet pressures The system designer is responsible for determining whether the process gas temperature may raise under any opera...

Страница 13: ...DA6 DA8 DA0 DA1 DAP SAP SLR 1 SLR 2 PTR 1 ALR 1 ULR 1 PGR 1 BQ BQ OPT 45 BQ CRYO 123 123 CRYO 123 OPT 45 123 OPT 46G 123 1 6 123 1 6 OPT 45 123 1 6 OPT 46G 123 1 6 S 123 1 6 S OPT 40 1000HP 1000HP OPT...