background image

5

27 July 2015 F29766C-F29766C EN

• Internal hydraulic coupler leakage into the case drain

line of the hydraulic coupler

• Too much oil flow through the implement connection of

the case drain line

Worn implement male couplers
1. Inspect the implement male coupler tips.
2. If worn or there is damage, replace.

Internal hydraulic coupler leakage into the case drain

line of the hydraulic coupler

If one of the remote couplers leaks, the remote cou-

pler will return oil through the case drain port to the

reservoir. If the remote coupler leaks, the remote

coupler could pressurize this drain port and cause

the remote couplers to pop out. To check for this

condition:
■ Inspect the implement male couplers (see above).
■ If the implement coupler tips are not worn or do not

have damage, install a gauge in the case drain port

in the remote manifold. This location is the plug just

above the motor return port.

BAIL15SBA0348AA

4

○ Energize each valve in extend and retract.
○ If  the  pressure  increases  when  you  energize  one

valve,  then  that  hydraulic  coupler  has  an  internal

leak.

NOTE: 

 Replace that hydraulic coupler cartridge and

the seals.

Too much oil flow through the implement connection

of the case drain line
○ The implement case drain tees into the coupler

of the case drain line. A high flow rate of the case

drain for the implement can cause pressure to build

up in the case drain line of the hydraulic coupler.

This high flow rate can cause the hydraulic couplers

to pop out of place. You normally see this condition

with the operation of a hydraulic fan or hydraulic

motor such as an air seeder in cold, ambient condi-

tions.
■ Perform a test for internal hydraulic coupler leak-

age (see above).

BAIL15SBA0349AA

5

Отзывы: