Temperature Low
Heater Set too Low
Heater Broken
Auto Top up Stuck Open
Adjust Heater Setting
Replace Heater
Check Float Valve
Temperature too High
Heater Broken
Heater Set too High
High summer ambient
temperature in store
Replace Heater
Adjust Heater Setting
UV Lamps not working
No Power to Lamp
Component Fault
Check black lamp leads
Check Electrical Supply
Contact CASCO
No Power to One System Electrical Fault
Check Extension lead
Fuse
Check mains plugs from
rack correctly connected
Contact Casco
No Power to All Systems
Electrical Fault on
Distribution
Check Main Store
Electrical Panel
System Pump Noisy
No water / Low level in
Pump Chamber
Pump failing
Switch off Pump and
allow reservoir to refill.
Check Top-Up System
Operation
Replace Pump
Contact CASCO
IMPORTANT
– If you cannot solve the problem with your system quickly you
should switch all system components off and move the aquarium livestock to
another correctly working system. Livestock must not be left for any significant
length of time in a system that is not working correctly.